Assessment of the AB HiFocusTM Mid Scala Electrode Movement Using Cone Beam Imaging Following Cochlea Implantation

Maastricht University Medical Center2 个研究点 分布在 1 个国家目标入组 14 人开始时间: 2013年9月最近更新:
适应症

试验速览

阶段
不适用
入组人数
14
试验地点
2
主要终点
movement of the electrode post-operatively in millimetres

研究概览

简要总结

One of the contributing factors to the variability in outcomes amongst Cochlear Implant (CI) recipients was reported to be the placement of the electrode array in the scala tympani. It seems that the correct placement of the electrode initially into the scala tympani and subsequent avoidance of dislocation into the scala vestibuli as the insertion progresses, is a key factor in achieving good speech perception outcomes. Another important aspect related to the performance is the achievement of consistent electrical coverage with the electrode. Data reported for electrodes of different manufacturers give depths ranging from 240 - 600 degrees showing the considerable variation across subjects. The HiFocus mid scala electrode was developed to cover one and a quarter turn and with the pre-curved design to be less susceptible to variations in individual cochlea dimensions and insertion techniques. A further mechanical feature of the pre-curved design is the avoidance of forces against the cochlear lateral wall and associated lower susceptibility of the electrode for moving out of the cochlea following insertion. Recently, a cone beam CT (CBCT) technique is being explored in the field of ENT with the potential to overcome some of the issues associated with the conventional CT techniques such as scattering, radiation and low isometric resolution. Images with comparable details to those of e.g. micro CTs are possible with much lower radiation dose. Modern imaging software i.e. 3D Slicer (www.slicer.org) may be used for 3D reconstruction, post processing and Brainsfit for registration. Registration is the alignment of two scans in the same coordinate system. This enables the identification of differences between two images recorded at time x and y. Once accurately superimposed any difference between the two images may be identified with an accuracy of 0.2 mm. Using these methods, one can assess the stability and the position of the electrode in the cochlea.

Objective: The primary objectives of this study are to evaluate the feasibility of using cone beam CT technique in combination with (high resolution) MRI to identify electrode movements following cochlear implant surgery and identify the inter-scalar position of the HFms electrode. The secondary objective is to quantify the average insertion depth and variations of the HFms electrode

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Diagnostic
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Adults 18y or older meeting the conventional Dutch CI criteria
  • The patient will receives the HiFocus Mid Scala electrode
  • No cochlear or neural abnormalities that could compromise the placement of the electrode as assessed by the CI surgeon

排除标准

  • Physical or non-physical contraindications for MRI or CT imaging
  • No additional disabilities that may prevent active participation and testing as per protocol

结局指标

主要结局

movement of the electrode post-operatively in millimetres

时间窗: 3 months

次要结局

未报告次要终点

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Guido Dees

MD, MSc

Maastricht University Medical Center