PV Cryoablation Efficacy Using Electrophysiological Endpoints and the New Generation ArticFont Advance ST Catheter (COR ADVANCE Study)

Hospital San Carlos, Madrid2 个研究点 分布在 1 个国家目标入组 25 人开始时间: 2015年8月最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
已完成
入组人数
25
试验地点
2
主要终点
Proportion of patients free-from AF, without antiarrhythmic drug therapy

研究概览

简要总结

The COR advance study is a non-randomized prospective single center study to assess the results of an electrophysiologically guided approach for PV cryoablation using the Arctic Front Advance ST® catheter together with the Achieve® mapping catheter in 25 patients with drug-refractory paroxysmal AF.

Methods Patient selection criteria will be the same that in the original COR study. All patients will be followed with a Reveal LINQ® cardiac monitor that will be implanted before ablation. The primary objective is the proportion of patients remaining free from atrial fibrillation recurrences without taking antiarrhythmic drugs 12 months after ablation. Secondary objectives are: AF-free survival without anti arrhythmic drugs 12 months after ablation, cumulative AF burden (number of AF episodes and percentage of time in AF) 12 months after ablation, percentage of the pulmonary veins with bidirectional block at the end of the procedure, and ablation time (from the onset of the first energy delivery to the end of the last energy delivery), procedure time (from femoral puncture to catheter removal), and fluoroscopy time.

Final results will be known 24 months after the first enrollment. Statistical analysis Continuous variables that are distributed normally according to the Shapiro-Wilk test will be presented as the mean [standard deviation], and the values will be compared with the t test. Continuous variables that do not follow a normal distribution will be presented as the median [25th to 75th percentile] and will be compared with the Mann-Whitney U test. Categorical variables between two groups with expected values <5 will be compared with the Fisher exact test. Otherwise, categorical variables will be compared with the chi-squared test. The AF-free survival functions will be represented as Kaplan-Meier curves. Data analyses will be done with JMP® (version 9.0.1, SAS Institute Inc., Cary, NC, USA) and Stata® (version 11.0, StataCorp LP; College Station, TX, USA).

详细描述

Background The Cryoenergy Or Radiofrequency [COR] trial is a randomized, single-center study that compared the efficacy of a anatomical simplified strategy for pulmonary vein cryoballoon ablation (2 shots per PV, 1 first-generation Arctic Front® catheter per patient and no additional touch-up applications to close residual gaps) versus the standard technique for pulmonary vein isolation using open-irrigated radiofrequency catheters (Navistar Thermocool®) with electrophysiological (Lasso®) and electroanatomical guidance (Carto 3®) in 50 patients with drug-refractory paroxysmal atrial fibrillation. All patients were followed with an implantable cardiac monitor (Reveal XT®).

The primary endpoint of the study (proportion of patients remaining free from atrial fibrillation recurrences without taking antiarrhythmic drugs 12 months after ablation) was met by 48% of patients treated with cryoenergy and 68% of patients treated with radiofrequency (OR 0.43 [95% confidence interval, 0.19 to 1.0]; P=0.05). This difference disappeared after adjustment for acute procedural outcome. In patients for whom all 4 PVs were blocked at the end of the procedure, there was no difference between group C and group R in the primary endpoint (67% versus 68%; P=0.94). Thus, the COR trial supports that: 1) complete PV conduction block is critical to the success of AF ablation; 2) despite the fact that the results of the anatomical cryoablation technique used in the COR study are superior to the previously published series of patients treated with PV cryoablation and followed by implantable monitors, results of cryoablation might be even better if we aim for PV conduction block. At present time, the availability of the Achieve® mapping catheter and the more efficient 2nd-generation cryoballoon ArcticFront Advance® catheter provides an opportunity to test a electrophysiologically guided PV cryoablation approach against conventional PV isolation with point-by-point radiofrequency ablation catheters.

The COR advance study is a non-randomized observational prospective single center study to assess the results of an electrophysiologically guided approach for PV cryoablation using the Arctic Front Advance ST® catheter together with the Achieve® mapping catheter in 25 patients with drug-refractory paroxysmal AF.

Methods

Inclusion criteria:

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Treatment
盲法
None

入排标准

年龄范围
18 Years 至 75 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Symptomatic recurrent paroxysmal AF
  • >2 episodes in the last 6 months
  • Refractory to 1 or more antiarrhythmic drugs
  • Anatomical pattern consisting of 4 pulmonary veins
  • Willing and capable of providing informed consent

排除标准

  • Patients that are <18 or >75 years old
  • Prior AF ablation
  • Prior cardiac surgery
  • Moderate to severe valvular heart disease
  • Anteroposterior diameter of the left atrium >50 mm
  • Hyperthyroidism, intracardiac thrombus, contraindications for anticoagulation, concomitant acute illness, pregnancy.
  • Unavailability for follow-up at our center for at least 1 year

研究组 & 干预措施

ArticFont Advance ST

Experimental

Patients undergoing PV isolation with the ArticFont Advance ST Cryoenergy Balloon Catheter

干预措施: ArticFont Advance ST Cryoenergy Balloon Catheter (Device)

结局指标

主要结局

Proportion of patients free-from AF, without antiarrhythmic drug therapy

时间窗: 12 months

次要结局

  • Time required to complete isolation (LA time)(intraoperative)
  • Cumulative AF burden(12 months)
  • AF-free survival, without antiarrhythmic drug therapy(12 months)
  • Proportion of PV with bidirectional block(intraoperative)