临床试验/NCT05775913
NCT05775913尚未招募不适用

Development of an Intrauterine Selective Balloon Catheter System for Transcervical Delivery of Selected Agents to the Fallopian Tube

Oregon Health and Science University0 个研究点目标入组 12 人开始时间: 2026年12月1日最近更新:
适应症

试验速览

阶段
不适用
状态
尚未招募
入组人数
12
主要终点
Expansion of arms and dual catheters

研究概览

简要总结

A single center study to evaluate the performance and optimize the design of a novel intrauterine catheter system intended as a nonsignificant risk medical device to aid in evaluating tubal patency as part of the initial diagnostic workup for infertility.

详细描述

In this study, the investigators will perform transcervical placement of a novel tubal selective delivery catheter system in a controlled clinical setting, using ultrasound imaging to evaluate device performance in a short procedure that will not require sedation or general anesthesia (local anesthesia may be used). The investigator will confirm the position of the device, inflate the balloons, and administer a small volume (10 mL) of an FDA-approved contrast foam. The investigator will then remove the device at the end of the procedure. This study will evaluate performance of the device, ease of use, and patient experience. It will also evaluate the patient experience before, during, and after the procedure. This device is meant to be used to assess tubal patency as part of the initial diagnostic workup for infertility, and use of the device may reduce the need for HSG.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Screening
盲法
None

入排标准

年龄范围
18 Years 至 50 Years(Adult)
性别
Female
接受健康志愿者

入选标准

  • Literate in English
  • Able to understand and sign an IRB-approved informed consent form
  • Willing to complete a pre-procedure questionnaire
  • Regular menstrual cycles (24- 38 days)
  • Good general health
  • Able and willing to comply with all study tests, procedures, and assessment tools
  • Uterine sound size between 6 - 10 cm
  • Agree to use a non-hormonal method of contraception or avoid vaginal intercourse during the catheter evaluation cycle
  • In compliance with cervical cancer screening guidelines per the American Society for Colposcopy and Cervical Pathology (ASCCP) guidelines without evidence of disease.
  • Alternatively, the subject must have had a colposcopy performed within the appropriate screen time frame, and prior to the study catheter insertion that showed no evidence of dysplasia requiring treatment or further diagnostic procedures or follow-up for at least 6 months

排除标准

  • Currently pregnant as confirmed by positive high-sensitivity urine pregnancy test
  • Currently using hormonal contraception. Must have at least one natural cycle (two menses) prior to participation if recently discontinued hormonal contraception.
  • Currently using an intrauterine device (IUD). Must discontinue at least 30 days prior to Visit 2
  • Allergy or hypersensitive to radio-opaque contrast, ExEm foam, both doxycycline and azithromycin (allergy to one not exclusionary if can take the alternative), or lidocaine
  • History or physical findings recognized as clinically significant by the investigator, such as symptoms of untreated or recent pelvic infection
  • History of involuntary female infertility
  • History of gynecologic surgery involving the uterus, fallopian tubes, or ovaries (except single cesarean section)
  • History of prior permanent contraception procedure (any technique, abdominal laparoscopic, or hysteroscopic)
  • Pelvic exam findings considered clinically-significant by the investigator such as uterine fibroids, pelvic tenderness, or prolapse
  • Inability to tolerate placement of a tenaculum and/or uterine sound during screening exam
  • Any congenital or acquired uterine anomaly that may complicate study drug placement, such as:
  • Submucosal uterine leiomyoma
  • Asherman's syndromes
  • Pedunculated polyps
  • Bicornuate uterus
  • Didelphys or uterine septa
  • Any distortions of the uterine cavity (e.g., fibroids), that, in the opinion of the investigator, are likely to cause issues during insertion, use or removal of the TSDS.
  • Known anatomical abnormalities of the cervix such as severe cervical stenosis, prior trachelectomy or extensive conization that, in the opinion of the investigator would prevent cervical dilation and device placement
  • Untreated or unresolved acute cervicitis or vaginitis
  • Known or suspected human immunodeficiency virus (HIV) infection or clinical AIDS
  • Screening transabdominal or transvaginal ultrasound findings with poor imaging quality, or anatomic abnormalities considered clinically important or likely to interfere with assessment of the test device, as assessed by the investigator

结局指标

主要结局

Expansion of arms and dual catheters

时间窗: During procedure immediately following attempt to position device

Expansion of arms and dual catheters in the two uterine cornua. Performance is categorized as one of three levels: excellent, acceptable, or fail. The number of participants in each category will be reported, with categories defined as: Excellent: Arms extend into bilateral cornua following transcervical insertion after initial expansion. Ultrasound confirms extension but is not needed Acceptable: Ultrasound is required to position arms, but expansion is successful after one or two attempts. Fail: Clinician is unable to position arms into cornua.

Clinical performance of catheter during insertion of device

时间窗: Immediately post-procedure within 30 minutes

Clinician impression of catheter performance during insertion of device. Performance is categorized as one of three levels: excellent, acceptable, or fail. The number of participants in each category will be reported, with categories defined as: Excellent: Clinician can place the insertion tube transcervically without dilation, and advance the obturator to expand the device without the use of imaging guidance. Acceptable: Cervical dilation required, but easy to advance the obturator to expand the device without the use of imaging guidance Fail: Unable to place the insertion tube

Clinician impression of device removal

时间窗: During procedure immediate following attempt remove device

Clinician impression of device removal. Performance is categorized as one of three levels: excellent, acceptable, or fail. The number of participants in each category will be reported, with categories defined as: Excellent: Clinician can deflate balloons, collapse frame, and withdraw insertion tube without difficulty at the end of procedure without the use of imaging guidance.

Delivery of saline

时间窗: During procedure immediate following attempt to administer saline

Delivery of saline. Performance is categorized as one of three levels: excellent, acceptable, or fail. The number of participants in each category will be reported, with categories defined as: Excellent: Successful administration of saline at low pressure (confirmed by ultrasound) with no leakage or bad connections. Acceptable: Some leakage of saline, but clinician is able to observe flow in tubes. Fail: Clinician unable to administer saline due to high pressure/pain, leakage or bad connections.

Inflation of dual balloons

时间窗: During procedure immediate following attempt to inflate balloons

Inflation of the dual balloons. Performance is categorized as one of three levels: excellent, acceptable, or fail. The number of participants in each category will be reported, with categories defined as: Excellent: Inflation of the dual balloons on first attempt by the clinician with no leakage or bad connections. This is confirmed by ultrasound. Acceptable: Inflation requires more than one attempt but is ultimately successful. Fail: Clinician is unable to inflate balloons due to high pressure or subject pain.

Delivery of ExEm foam

时间窗: During procedure immediate following attempt to administer ExEm foam

Delivery of ExEm foam. Performance is categorized as one of three levels: excellent, acceptable, or fail. The number of participants in each category will be reported, with categories defined as: Excellent: Delivery of foam at low pressure with confirmation of tubal patency via ultrasound and with no leakage or bad connections. Acceptable: Some leakage of ExEm in uterine cavity, but clinician is able to observe flow in tubes. Fail: Clinician unable to administer ExEm due to high pressure/pain, leakage or bad connections.

次要结局

  • Tolerability and ease of use - Patient experience evaluation(Pre-procedure, during procedure, immediately post-procedure, 15 minutes post-procedure)
  • Tolerability and ease of use - Provider experience evaluation(Immediately Post-procedure (within 30 minutes))

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Jeffrey Jensen

Professor

Oregon Health and Science University