Image-guided Cochlear Implant Programming (IGCIP)
试验速览
- 阶段
- 不适用
- 状态
- Enrolling By Invitation
- 入组人数
- 150
- 试验地点
- 1
- 主要终点
- AzBio Sentence Scores at +5 Signal to Noise Ratio (SNR)
研究概览
简要总结
Cochlear implants are surgically implanted devices which restore the ability to hear to the hearing impaired. While remarkably successful, even in the best of performers restoration of hearing to levels of normal listeners is unusual. Approximately 3 weeks after surgery, cochlear implants are activated via mapping - a process in which each individual electrode (FDA approved cochlear implants have between 12 and 22 electrodes) is turned on and the stimulus level adjusted to a level that is comfortable and beneficial to the recipient. At present, this standard of care mapping procedure is performed without knowledge of the physical location between the cochlear implant electrodes and the neural interface. The research team has developed a new method of mapping using post-operative CT scans and image processing to specify the physical relationship between the cochlear implant electrodes and the neural interface allowing customized mapping. Using this information, the investigators deactivate sub-optimally positioned electrodes. The investigators term this "Image-guided Cochlear Implant Programming" (IGCIP). The study collects data in a prospective fashion for those CI recipient undergoing IGCIP.
详细描述
Over 320,000 individuals have received cochlear implants (CIs) to restore hearing to the hearing impaired. Commercially available CIs have 12, 16, or 22 independent electrodes (the number is dependent on the manufacturer of the CI) which cover the entire frequency spectrum of the cochlea from 20,000 Hertz (Hz) at the base of to 200Hz at the apex. After implantation, an audiologist individually adjusts stimulation levels of each electrode following which all electrodes are turned on such that the whole frequency spectrum of speech can be appreciated. This is known as "standard of care" (SOC) programming. While postoperative speech understanding is significantly better than preoperative levels, even the best performers complain that the fidelity of natural hearing is not reproduced. Additionally, a significant minority achieves poor outcomes despite normally functioning equipment for reasons that are unknown but likely relate to poor neural survival; however, this cannot be confirmed as postmortem histopathology is required to accurately document spiral ganglion cell count. In recent years much attention has focused on the interface between the cochlear implant electrodes and the auditory neurons they are stimulating. Technological improvements at Vanderbilt in imaging processing have made it possible to determine the location of each electrode array in relationship to the frequency spectrum of the cochlea. Using this information, the investigators have developed a new method of CI programming which they call image-guided cochlear implant programming, or IGCIP in which sub-optimally placed electrodes are turned-off or deactivated. Sub-optimally placed electrodes are defined as ones for which their neighboring electrodes are in closer proximity to the site of their neural stimulation. By deactivating sub-optimally positioned electrodes, channel interaction is reduced allowing a cleaner signal to be presented to the auditory nerve. The purpose of the study is to prospectively collect audiological outcomes on patients undergoing IGCIP. The investigators hypothesize that CI recipients will perform better with IGCIP as compared to SOC.
Cochlear implant recipients who have reached asymptotic improvement in performance with SOC will be offered enrollment. They will undergo post-operative CT scanning to determine the relationship between the cochlear implant electrodes and the neural interface. Recommendations regarding deactivation of sub-optimally placed electrodes will be communicated to the audiology team who, if in their clinical judgement deems deactivation of these electrodes reasonable, will implement the changes for a 1 month trial. The participant will return at 1 month to have audiological assessment as per the clinical standard of care. Based on these results, which will be shared with the patient, the patient can choose to use IGCIP or SOC for long term cochlear implant programming.
研究设计
- 研究类型
- Interventional
- 分配方式
- Na
- 干预模型
- Single Group
- 主要目的
- Treatment
- 盲法
- None
入排标准
- 年龄范围
- 18 Years 至 90 Years(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Adults aged 18 to 90 years that have undergone diagnostic testing for sensorineural hearing loss and have received a cochlear implant with asymptotic improvement in performance with SOC programming will be considered eligible for the study.
排除标准
- •Age < 18 years or > 90 years
- •Non-English speaking (because our audiological speech testing battery is validated for English speakers)
- •Pregnancy which is a contraindication for elective CT scanning and surgery
研究组 & 干预措施
Image-guided Cochlear Implant Programming (IGCIP)
Cochlear implant programming using IGCIP.
干预措施: Image-Guided Cochlear Implant Programming (Other)
结局指标
主要结局
AzBio Sentence Scores at +5 Signal to Noise Ratio (SNR)
时间窗: Month 1 post cochlear implant activation
次要结局
- Minimum Speech Test Battery(Month 1 post cochlear implant activation)
研究者
Jack Noble
Research Assistant Professor, Electrical Engineering and Computer Science
Vanderbilt University