跳至主要内容
临床试验/NCT05692362
NCT05692362Enrolling By Invitation不适用

Measure Airway Compliance by Endobronchial Optical Coherence Tomography

The First Affiliated Hospital of Guangzhou Medical University1 个研究点 分布在 1 个国家目标入组 30 人开始时间: 2023年3月1日最近更新:
适应症

试验速览

阶段
不适用
状态
Enrolling By Invitation
发起方
入组人数
30
试验地点
1
主要终点
Airway Compliance of different airway generation

研究概览

简要总结

Optical Coherence Tomography (OCT)is a novel, non-invasive, high resolution special optical imaging techniques. In airway, Measure airway area and airway wall thickness is the most usage of Endobronchial Optical Coherence Tomography (EB-OCT). Recently, the new protocol of EB-OCT is used to measure airway compliance, We will establish a new methodology of EB-OCT for measuring airway compliance, which will provide a new means to study respiratory diseases.

研究设计

研究类型
Observational
观察模型
Case Control
时间视角
Cross Sectional

入排标准

年龄范围
18 Years 至 70 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Regardless of gender, age 18-70 years old;
  • Patients with clinical diagnosis of pulmonary nodules, COPD, asthma or restrictive pulmonary diseases;
  • Can tolerate bronchoscopy patients;
  • Sign the informed consent form.

排除标准

  • Suffering from any of the following respiratory diseases: bronchiectasis, etc;
  • Have malignant tumors that are not completely remission or cured;
  • The patient's systemic infection is not controlled;
  • Recent use of immunosuppressants, recent use of anticoagulants (such as warfarin or aspirin within 2 weeks of drugs that affect blood clotting function);
  • Serious other systemic diseases: myocardial infarction, unstable angina, cirrhosis, acute glomerulonephritis, etc.;
  • Those who are positive for syphilis, HIV, HBV, and HCV antibodies;
  • Patients with coagulation dysfunction diseases, such as hemophilia, giant platelet syndrome, platelet weakness, etc.;
  • Severe renal impairment, serum creatinine > 1.5 times the upper limit of normal value;
  • Liver disease or liver function impairment: ALT, AST, total bilirubin > 2 times the upper limit of normal value;
  • Those with a history of mental illness or suicide, a history of epilepsy or other central nervous system diseases;
  • 12-lead ECG showing severe arrhythmias (such as ventricular tachycardia, frequent supraventricular tachycardia, atrial fibrillation, atrial flutter, etc.) or conduction abnormalities of the heart of grade II and above;
  • Those who are allergic to catheters and related materials required for experiments;
  • Subjects who have received any other clinical studies within 3 months prior to enrollment;
  • Those who have poor compliance and difficulty in completing the study;
  • Any condition that the clinician believes may increase the risk to the patient or interfere with the clinical study.

结局指标

主要结局

Airway Compliance of different airway generation

时间窗: 2023/01/01-2024/12/31

Airway compliance is the property of the airway lumen area to change as pressure changes. This is caused by airway structure, the small airway without cartilage compared with medium and large airways, so the compliance would be different. But the methods of measuring airway compliance is difficult, In this research, we will use OCT to measure airway area (mm2), and record the airway pressure(cmH2O), The ratio of area change to pressure change is the compliance, we will measure and compare the compliance of different airway generation.

次要结局

  • Airway Compliance of different people(2023/01/01-2024/12/31)

研究者

发起方
The First Affiliated Hospital of Guangzhou Medical University
申办方类型
Other
责任方
Principal Investigator
主要研究者

Xu Hang

Dierctor of Intervetional Pulmonary Center

The First Affiliated Hospital of Guangzhou Medical University

研究点 (1)

Loading locations...

相似试验

Measure Airway Compliance by Endobronchial Optical... | 临床试验