跳至主要内容
临床试验/NCT06260670
NCT06260670已完成不适用

Electrographic Flow Mapping Electrogram Validation in Patients With Persistent Atrial Fibrillation (FLOW EVAL-AF)

Ablacon, Inc.1 个研究点 分布在 1 个国家目标入组 10 人开始时间: 2022年9月1日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
已完成
发起方
Ablacon, Inc.
入组人数
10
试验地点
1
主要终点
Number of Participants With Successful Acquisition of EGF Mapping and High Density Mapping

研究概览

简要总结

FLOW EVAL-AF is a prospective, observational, single center pilot trial. The FLOW EVAL-AF trial is designed to identify driver sources in patients with persistent or longstanding persistent AF using EGF mapping and describe the activation patterns observed from concomitant high density mapping of those regions.

详细描述

It is hypothesized that initiation and propagation of atrial fibrillation (AF) is dependent, at least in part, on rapid atrial stimulation from focal sources. It is debated whether the mechanism of arrhythmogenesis at these foci is abnormal automaticity, triggered activity, microreentry or rotational reentry. However, after activation emerges from these "driver" sites, fibrillatory conduction ensues resulting in the disorganized conduction pattern of AF. Conventional mapping systems can either achieve high spatial resolution by sequential tachycardia beats following a fixed intra-atrial activation pattern (as in macro reentrant atrial flutter), or high temporal resolution with very low spatial resolution achieved through multielectrode basket catheters. Activation mapping in AF with commercially available mapping systems has been unsuccessful in identifying driver sites because atrial activation patterns change on a beat-to-beat basis precluding the use of sequential mapping approaches, and real-time mapping with basket electrodes lacks sufficient resolution to delineate the complex patterns of conduction.

Electrographic Flow (EGF) mapping (AblaMap®, Ablacon, Inc, Wheat Ridge, CO) is a unique method to assess dominant patterns of intra-atrial conduction during ongoing atrial fibrillation and has been previously described. Recordings from a multielectrode basket catheter are analyzed for electrical activation vectors over sequential 2-second segments during a 60 second acquisition period. Patterns of reproducible vector activation are used to identify driver sources for the atrial fibrillation (AF). Multiple sources are often identified in patients with persistent AF. It is anticipated that substrate modification of these source regions will eliminate the AF drivers and result in a favorable response to catheter ablation as shown in a previously published retrospective analysis.

The FLOW EVAL-AF trial is designed to identify driver sources in patients with persistent or longstanding persistent AF using EGF mapping and describe the activation patterns observed from concomitant high density (HD) mapping of those regions. FLOW EVAL-AF is a prospective, observational, single center pilot trial.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Diagnostic
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者
否

入选标准

  • •Scheduled to undergo elective catheter ablation of AF
  • •History of persistent or longstanding persistent AF
  • •Able to provide written informed consent prior to the procedure
  • •Age ≥18 years

排除标准

  • •Presence of a permanent pacemaker or other transvenous pacing/defibrillation leads
  • •Presence of a prosthetic mitral heart valve
  • •Known reversible causes of AF
  • •Any cerebral ischemic event (strokes or transient ischemic attacks) which occurred during the 6-month interval preceding the consent date
  • •History of thromboembolic event within the past 6 months or evidence of intracardiac thrombus at the time of the procedure
  • •Unable to provide own informed consent

研究组 & 干预措施

EGF Mapping

Experimental

Subjects will be treated with catheter ablation of atrial fibrillation as is clinically indicated according to standard hospital ablation procedures (pulmonary vein isolation in de novo, pulmonary vein isolation touch-up in redo).

In addition, subjects will receive electrographic flow mapping (EGF) and concomitant high density mapping to collect electrogram patterns and morphology using both mapping methods.

干预措施: Electrographic Flow™ Mapping using Ablamap® Software and FIRMap™ Catheter (Device)

结局指标

主要结局

Number of Participants With Successful Acquisition of EGF Mapping and High Density Mapping

时间窗: Intraprocedural

Number of participants with successful acquisition of global electrographic flow (EGF) maps from each of the right and left atria and high density electrogram acquisitions, from at least 3 basket positions in each atrium.

次要结局

  • Total Number of EGF-Identified Sources(Intraprocedural)

研究者

发起方
Ablacon, Inc.
申办方类型
Industry
责任方
Sponsor

研究点 (1)

Loading locations...

相似试验