跳至主要内容
临床试验/NCT02688010
NCT02688010已完成不适用

Effect of Reduced Noise Levels and Cycled Light on Visual and Neural Development in Preterm Infants

Children's Hospital of Fudan University1 个研究点 分布在 1 个国家目标入组 109 人开始时间: 2016年1月8日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
已完成
入组人数
109
试验地点
1
主要终点
Flash visual evoked potentials (FVEP) at 4 weeks of age

研究概览

简要总结

Noise is a hazard for newborn. In 1997, the American Academy of Pediatrics determined that safe sound levels in the neonatal intensive care unit (NICU) should not exceed 45 dB which has been rarely achieved. High intensities of noise have several negative effects on preterm newborns. Also, they are exposed to either continuous bright light continuous near darkness or unstructured combination of the two during their hospitalizations. The investigators primary objective is to determine the impact of reduced noise levels and cycled light on growth parameters and visual development in preterm infants.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Supportive Care
盲法
Quadruple (Participant, Care Provider, Investigator, Outcomes Assessor)

入排标准

年龄范围
1 Day 至 7 Days(Child)
性别
All
接受健康志愿者
否

入选标准

  • •<37 gestational weeks preterm infants and >1250g birth weight

排除标准

  • •Major congenital anomaly and infection prior to enrolment
  • •Infants with surgical issues

研究组 & 干预措施

Control

No Intervention

No specific noise reduction strategies to restrict noise exposure less than 45 dB combined with either continuous bright light or continuous near darkness or unstructured combination of the two during the hospitalization.

Noise reduction and cycled light

Experimental

Reduced noise exposure (sound levels <45 dB) and cycled light (approximately 12 hours of light on and 12 hours of light off).

干预措施: Noise reduction and cycled light (Behavioral)

结局指标

主要结局

Flash visual evoked potentials (FVEP) at 4 weeks of age

时间窗: at 4 weeks of age

FVEP is recorded from each eye individually after they fall asleep. Three silver-sliver chloride electrodes are placed according to 10-20 International system with active electrode at Oz (1-2 cm above inion), reference electrode at Fz and ground electrode at Cz. Scalp-electrode impedance is usually below 5kΩ but always below 10kΩ. Flash stimulus (2 Hz.) is given by light emitting diode goggles simulator at a distance of 2 cm to one eye at a time. 100 responses are averaged for each eye automatically in the Nicolet Viking Quest visual electrophysiological device at 1s total sweep time. Band pass filters are set at 0.1-75 Hz. The reproducibility of the responses is ensured by repeating the test two or more times. Responses with excessive artifacts are automatically rejected. The parameters of P1, N1, P2, N2, P3, and N3 of the FVEP are stored and subsequently assessed by ophthalmologist blinded to the infant's clinical course.

Bayley Scales of Infant Development, Second Edition (BSID-III) at 18 months of age

时间窗: at 18 months of age

Neurodevelopment outcome is measured with the Bayley Scales of Infant Development, Second Edition (BSID-III) at corrected gestational age of 18 month, assessed by the physician from department of child health care who was blinded with respect to the subjects. Mental and motor scores were calculated by the BSID-III Mental Developmental Index (MDI) and Psychomotor Developmental Index (PDI). The subject's neurodevelopmental outcome was classified as delayed if either score was less than 70.

次要结局

  • Time to establish full enteral feeding(birth till discharge from hospital (up to 3 months))
  • Incidence of nosocomial infection(up to 3 months)
  • Incidence of intraventricular hemorrhage(1 month)
  • Incidence of retinopathy of prematurity(up to 3 months)
  • Weight at discharge(birth till discharge from hospital (up to 3 months))
  • Head circumferences at discharge(up to 3 months)
  • Incidence of bronchopulmonary dysplasia(at corrected gestational age of 36 weeks)

研究者

申办方类型
Other
责任方
Sponsor

研究点 (1)

Loading locations...

相似试验