Pilot Study: Post-Operative Outcomes of Low Thermal Dissection vs. Traditional Electrosurgery for Mastectomy Breast Flap Creation With Immediate Breast Reconstruction
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 入组人数
- 20
- 试验地点
- 4
- 主要终点
- Perfusion
研究概览
简要总结
Low thermal dissection devices have been introduced as a tool to improve surgical outcomes. PlasmaBlade, a low thermal dissection device, has shown to be associated with effective cutting, and significantly lower temperature than traditional electrosurgical dissection device. Thus, low thermal devices would improve flap perfusion by decreasing the thermal injury resulted by the dissection. Looking into the use of low thermal devices in cases of mastectomy and immediate breast reconstruction has not been documented. The aim of this study is to determine if there are clinical flap perfusion, surgical site drainage, and pain scores differences between mastectomy flaps created using low thermal dissection device and those done with the standard care of Bovie cautery in order to warrant a formal study.
详细描述
This is a single-blinded, randomized, controlled clinical trial comparing postoperative flap perfusion and surgical site drainage between patients randomized to breast flap creation by PlasmaBlade (low thermal dissection intervention) on one breast and by a Bovie cautery (Control) for the contralateral breast flap. Candidates will have elected to undergo bilateral post-mastectomy immediate breast reconstruction (IBR). Participants meeting inclusion criteria will be enrolled and baseline data collection completed prior to randomization and surgery.
Patients and the plastic surgeon will be blinded in regards to intervention randomization. Only the oncology surgeon has knowledge of which device used for each breast flap. However, after the plastic surgeon makes the assessment of the flap, he/she will be unblinded in order to complete the reconstruction procedure using the same dissection device on the same side it was used for in the mastectomy procedure. Patient-specific surgical details will be recorded intraoperatively. Following the surgery, post-operative flap perfusion will be recorded using SPY imaging system. Surgical site drainage will be measured until drainage removal. Post-operative pain (Visual Analog Scale for Pain) and the occurrence of adverse events will be recorded up until discharge and 30-days postoperative follow up visit.
研究设计
- 研究类型
- Interventional
- 分配方式
- Randomized
- 干预模型
- Single Group
- 主要目的
- Device Feasibility
- 盲法
- Single (Investigator)
入排标准
- 年龄范围
- 18 Years 至 75 Years(Adult, Older Adult)
- 性别
- Female
- 接受健康志愿者
- 否
入选标准
- •Women aged 18-75 years.
- •Choose bilateral mastectomy followed by immediate breast reconstruction.
- •Have no inflammatory breast cancers.
- •Have not had radiotherapy before mastectomy.
- •Understand the study purpose, requirements, and risks.
- •Be able and willing to give informed consent.
排除标准
- •Active connective tissue disease.
- •History of, or plan to undergo irradiation of the breasts.
研究组 & 干预措施
Breast flap creation with Bovie Cautery
During participant's scheduled bilateral mastectomy, breast flap will be created using standard Bovie cautery on the breast contralateral to the one that was created using PlasmaBlade.
Breast flap creation with PlasmaBlade
During participant's scheduled bilateral mastectomy, breast flap on one breast will be created using low thermal dissection device (PlasmaBlade) on one breast and standard Bovie cautery in the contralateral breast.
干预措施: PlasmaBlade 3.0S (Device)
结局指标
主要结局
Perfusion
时间窗: Day of Surgery
Plastic surgeon objectively assesses degree of perfusion with the SPY Perfusion Assessment system (intra-operative fluorescence imaging system). Plastic surgeon describes perfusion as Left better than Right, Right better than Left, or both sides equally perfused.
次要结局
- Drainage(Up to 14 days post-operatively.)
- Pain Scores(Days 1,2,3,7,30 Post-operatively)