跳至主要内容
临床试验/NCT03947060
NCT03947060已完成不适用

BI-SENSES: Validation of Nasal Versus Frontal Placement of the SedLine® Sensor Through Processed Electroencephalography in Adult Patients Undergoing General Anesthesia

Cleveland Clinic Abu Dhabi1 个研究点 分布在 1 个国家目标入组 40 人开始时间: 2019年12月1日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
40
试验地点
1
主要终点
Validation of nasal SedLine® EEG sensor position for monitoring the depth of anesthesia using processed electroencephalograph values

研究概览

简要总结

SedLine® Brain Function Monitoring provides real-time insight into a patient's depth of anesthesia with bilateral data acquisition and processing of electroencephalogram (EEG) signals. Four active EEG leads collect data from the frontal lobe with a sensor position on the patient's forehead.

Whenever a frontal approach for neurosurgical procedures is required or the frontal placement of the EEG is not indicated, it would not be possible to place the SedLine® .

Numerous studies have analyzed the change of position and the application of alternative positions for other devices used in assessing the depth of anesthesia. Albeit, yet to date, there is no study that analyzed the application of alternative positions for the SedLine® sensor.

详细描述

The purpose of study is to compare the standard forehead placement versus a nasal placement of SedLine® sensor for neuromonitoring.

The hypothesis is that placing the central sensors in the montage approximately 2 cm below the standard recommended placement, across the nasal bridge and then running under the eyes to the normal temporal leads placement would put the entire montage out of the operative field and would still have corresponding values and EEG signals.

The primary outcome measure is to monitor and compare processed electroencephalograph (EEG) values (PSi- Patient State Index, SEFL- Spectral Edge Frequency Left, SEFR- Spectral Edge Frequency Right, SR-Suppression Ratio, EMG-Electromyography, ARTF-Artifact) and EEG waveforms, on both sensors (standard-Forehead and alternative-Nasal)

Other parameters that will be measure are patient demographics (age, sex, surgery, ASA status, weight, height, BMI).

研究设计

研究类型
Observational
观察模型
Cohort
时间视角
Prospective

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Patients older than 18 years of age, both genders.
  • Patients undergoing simple or complex surgery.
  • American Society of Anesthesiologists Classification (ASA) score I to III.

排除标准

  • American Society of Anesthesiologists Classification (ASA) score IV and V.
  • Emergency cases
  • Cognitive/Mentally impaired or unable to provide consent
  • Previous neurological problems affecting EEG
  • Use of sedative or drugs that can alter EEG readings
  • Patients under head and neck surgery

结局指标

主要结局

Validation of nasal SedLine® EEG sensor position for monitoring the depth of anesthesia using processed electroencephalograph values

时间窗: One year

Determine whether it is possible to apply an alternative SedLine® EEG sensor position in a situation where a standard-forehead position is not possible.

次要结局

未报告次要终点

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Boris Tufegdzic

Asst Prof Dr Boris Tufegdzic

Cleveland Clinic Abu Dhabi

研究点 (1)

Loading locations...