跳至主要内容
临床试验/NCT03087812
NCT03087812已完成不适用

Durability of Flexible Ureteroscopes and Causes of Infection During Flexible Ureterorenoscopy

Clinical Research Office of the Endourological Society1 个研究点 分布在 1 个国家目标入组 400 人开始时间: 2015年12月最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
400
试验地点
1
主要终点
Microbiological load

研究概览

简要总结

This is an observational study in which data on consecutive patients who undergo ureterorenoscopy with the use of a flexible ureterorenoscope are collected. In total 20 new ureteroscopes are usedfrom Olympus andfrom Storz) to study the durability of the ureteroscopes and the possible microbiological load.

详细描述

This is an observational study in which data on consecutive patients who undergo ureterorenoscopy with the use of a flexible ureterorenoscope are collected. In total 6 new ureteroscopes are used (3 from Olympus and 3 from Storz) to study the durability of the ureteroscopes and the possible microbiological load.

Before the procedure is started the endoscope is tested for its microbiological load in two different ways:1. Shake the tip of the flexible ureterorenoscope 5 seconds in a sterile container filled with 10 cc of NaCl 0.9% 2. Flush the working channel of the ureterorenoscope with 10 cc of NaCl 0.9% and collect the sample in a sterile container.

After the procedure is finished, the endoscope is tested for its microbiological load in two different ways:

  1. Shake the tip of the flexible ureterorenoscope 5 seconds in a sterile container filled with 10 cc of NaCl 0.9% 2. Flush the working channel of the ureterorenoscope with 10 cc of NaCl 0.9% and collect the sample in a sterile container.

Transfer all samples to the lab as soon as possible but at least within four hours after collecting the samples.

研究设计

研究类型
Observational
观察模型
Cohort
时间视角
Prospective

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Patient presented with a diagnosis to undergo a ureterorenoscopy using a flexible ureterorenoscope
  • over 18 years
  • has signed informed consent
  • the patient is being treated with the designated flexible ureterorenoscope

排除标准

  • 未提供

结局指标

主要结局

Microbiological load

时间窗: 2 years

To evaluate the pre-operative microbiological load of the tip and the working channel of the most common used flexible ureteroscopes, after high level disinfection

次要结局

  • Durability(2 years)
  • Factors affecting durability(2 years)

研究者

发起方
Clinical Research Office of the Endourological Society
申办方类型
Other
责任方
Sponsor

研究点 (1)

Loading locations...

相似试验