跳至主要内容
临床试验/NCT05334199
NCT05334199已完成不适用

Evaluation of Treatment With Biodegradable Airway Stent for Post Lung Transplant Airway Complication

University Medical Center Groningen2 个研究点 分布在 1 个国家目标入组 20 人开始时间: 2019年4月2日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
20
试验地点
2
主要终点
Adverse events

研究概览

简要总结

Introduction and rationale

Benign airway stenosis or malacia is a frequent complication of lung transplantation occurring in 4-24% of patients, most often occurring two to nine months post-transplant. Initial therapeutic approach consists of conservative endobronchial treatment with recurrent balloon dilatation, radial incision, and electro cautery. For severe case of recurrent stenosis or malacia, airway stent placement can be considered. Different types of airway stent exist, for instance self-extendable metallic stent (SEMS), silicone stent and biodegradable airway stent. Conventional airway stents (SEMS, silicone) are associated with complications as granulation tissue and recurrent infections and can be difficult to remove. Newly developed biodegrabale stents are made of polydioxanone and disintegrate after a period of time are thought to have less side effects, and has been standard of care for the last few years. A sub selection of patients have been treated with conventional stent before treated with biodegradable stent.

Research question

  • To assess the efficacy and efficiency of biodegradable airway stent.
  • Compare occurrence of adverse events such as infection, dislocation, in stent granulation and difficulty of removal to conventional metallic or silicone stents.
  • Asses if biodegradable stent lead to improvement of lung function.
  • Assessment of the life span of biodegradable stents.

详细描述

  • Background Recurrent airway stenosis or malacia can be treated with airway stents. Conventional airway stents, for instance self-extendable metallic stent (SEMS) and silicone stent are associated with adverse events as recurrent infection or granulation tissue and can be difficult to remove because of in stent-granulation. Therefore they are used with restraint for benign airway problems. Biodegradable stents are made of polydioxanone and disintegrate after a period of time. They are thought to be well tolerated and associated with less adverse events compared to traditional airway stent and have been used as standard care for multiple years.

  • Main research question

  • To assess the efficacy and efficiency of biodegradable airway stent

  • Compare occurrence of adverse events such as infection, dislocation, in stent granulation and difficulty of removal to conventional metallic or silicone stents.

  • Asses if biodegradable stent lead to improvement of lung function.

  • Assessment of the life span of biodegradable stents.

  • Design (including population, confounders/outcomes) Retrospective cohort study of patients with airway stenosis or malacia treated with biodegradable airway stent from 2019 in the UMCG and Amsterdam UMC.

  • Expected results

  • Less adverse events, hospital admittance and need for bronchoscopic interventions compared to patients treated with conventional stents. No complications associated with removal of stents.

  • Life span around 4 months

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Treatment
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Patients who underwent a lung transplantation and developed airway stenosis or malacia with airway stent requirement

排除标准

  • 未提供

结局指标

主要结局

Adverse events

时间窗: 4 months after placement

Adverse events associated with airway stents

次要结局

  • Change in FEV1(1 week post placement)
  • Change in FVC(1 week post placement)
  • Time to need for new stent placement(6 months after placement)

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Dirk-Jan Slebos

Prof. dr.

University Medical Center Groningen

研究点 (2)

Loading locations...

相似试验