NCT01381068已完成不适用
Quantitative End Tidal CO2 Monitoring in the Delivery Room: Can we Prevent Hypo/Hypercapnia Upon Admission to the NICU?
Neil Finer2 个研究点 分布在 1 个国家目标入组 50 人开始时间: 2009年10月最近更新:
适应症
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 发起方
- 入组人数
- 50
- 试验地点
- 2
- 主要终点
- PCO2 Level Outside of Desired Range (40-60 mmHg)
研究概览
简要总结
This is a trial evaluating the use of an end tidal CO2 monitor during ventilation in the delivery room. The use of the monitor is compared with clinical assessment of ventilation. The hypothesis is that using the monitor would results in a decrease in the incidence of hypo- or hypercapnia on admission to the NICU.
研究设计
- 研究类型
- Interventional
- 分配方式
- Randomized
- 干预模型
- Parallel
- 主要目的
- Treatment
- 盲法
- None
入排标准
- 年龄范围
- — 至 15 Minutes(Child)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Need for ventilation in the delivery room
排除标准
- •Tracheal suctioning for meconium
- •Congenital Diaphragmatic Hernia
- •Suspected hypoplasia of the lungs
- •Oligohydramnios <28 weeks gestation or AFI<5
- •Known or suspected airway anomaly
- •Mother not speaking English or Spanish
- •Refusal of consent
结局指标
主要结局
PCO2 Level Outside of Desired Range (40-60 mmHg)
时间窗: Admission to NICU, approximately 1 hour of life
This outcome will be obtained from the first available blood gas after admission to the NICU.
次要结局
- Oxygen Use at 36 Weeks(Hospital course, approximately 2-3 months)
- Duration of Ventilation(Duration of the hospital course, approximately 2-3 months)
- Incidence of Pneumothorax/Airleak(Hospital course, approximately 2-3 months)
- Number of Patients Ventilated on NICU Admission(On NICU admission, approximately 15 minutes of life)
- Systemic Blood Flow - as Measured by Supervior Vena Cava (SVC) Flow(Within 12 hours of life)
- End Tidal CO2 Levels(At the conclusion of resuscitation, approximately 15 minutes of life.)
研究者
Neil Finer
Professor Emeritus
University of California, San Diego
研究点 (2)
Loading locations...
相似试验
已完成
不适用
Carbon Dioxide InvestigationIntubationTracheostomyLaryngeal MaskNCT06715410GE Healthcare42
已完成
不适用
Comparison of End-tidal Carbon Dioxide (ETCO2) Measured by Transportable Capnometer (EMMATM) and the Arterial pCO2 in General AnesthesiaEnd Tidal Carbon Dioxide of Patients Undergoing General AnesthesiaNCT02184728Inje University35
已完成
不适用
The Measurements of End-tidal Carbondioxide LevelsOther Disorders of the Eye Following Cataract SurgeryNCT03923283Duzce University42
撤回
不适用
Employing End Tidal Capnography in Continuous Flow Ventricular Assist Device PatientsHeart DiseaseCardiovascular DiseaseCardiomyopathyNCT02838355Emory University
招募中
不适用
Assessment of End-tidal Carbon Dioxide Levels in Respiratory DiseaseRespiratory DiseaseNCT05188976National Hospital Organization Minami Kyoto Hospital40
