跳至主要内容
临床试验/NCT01145079
NCT01145079已完成4 期

A New Strategy Regarding Discontinuation of Dual Antiplatelet; Real Safety and Efficacy of a 3-month Dual Antiplatelet Therapy Following Zotarolimus-eluting Stents Implantation (RESET Trial)

Yonsei University2 个研究点 分布在 2 个国家目标入组 982 人开始时间: 2009年5月最近更新:
适应症
干预措施

试验速览

阶段
4 期
状态
已完成
入组人数
982
试验地点
2
主要终点
Primary Outcome The composite of cardio-vascular death, MI, stent thrombosis, TVR and bleeding (minor or major) following randomly assigned DES implantation

研究概览

简要总结

Drug-eluting stents (DES), markedly reducing the neointimal hyperplasia after stent implantation compared with bare-metal stents (BMS), have improved angiographic and clinical outcomes in the complex lesions and patients with high risks. However, currently, the fatal events related with stent thrombosis still occur and are the major limitation of the use of DES. Especially, late or very late thrombosis after DES implantation is an uncommon but life-threatening fatal complication presented with sudden death or myocardial infarction (MI) causing heart failure. The most powerful predictor for stent thrombosis is the discontinuation of clopidogrel. In consideration of current data regarding stent thrombosis and clinical situation of discontinuation of antiplatelet, zotarolimus-eluting stent (ZES) [Endeavor®, Medtronic Vascular, Santa Rosa, CA] might be anticipated to be safer than other DES during the long-term follow-up owing to healthy endothelialization. Endeavor® stent was consists of zotarolimus, thin-strut, cobalt-chromium alloy stent platform (DriverTM stent; Medtronic Vascular, Santa Rosa, CA), and phosphorylcholine coating. The ENDEAVOR II study demonstrated clinically and statistically significant improvement in all of study endpoints, including a 47 percent reduction in the primary endpoint of target vessel failure (TVF). In addition, the ENDEAVOR II trial showed a 0.5 percent rate of stent thrombosis at 30 days - with no late thrombosis beyond 30 days and no late stent malapposition. Because reendothelialization after ZES implantation may occur within 3 months, 3-month dual antiplatelet therapy is recommended in many clinical trials and real world practice. Shorter maintenance of dual antiplatelet therapy might minimize the risk for stent thrombosis in cases of discontinuation of antiplatelet and prevent waste medications and bleeding complications related with dual antiplatelet therapy. However, there have been no non-inferior or superior data of ZES considering all these circumstances. Therefore, the investigators hypothesize that ZES with 3-month dual antiplatelet therapy may be safe and beneficial in patients with coronary artery disease during follow-up than other DES, in spite of higher late lumen loss. To test this hypothesis, the investigators will perform a multi-center, randomized, prospective trial aimed at demonstrating the efficacy of the ZES versus other DES in patients with coronary artery disease in real world practice.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Treatment
盲法
None

入排标准

年龄范围
20 Years 至 85 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Coronary artery disease including stable angina, unstable angina, acute non-ST elevation myocardial infarction and acute ST elevation myocardial infarction
  • Age 20 years of older
  • Patients with typical chest pain or evidences of myocardial ischemia (e.g., stable, unstable angina, silent ischemia and positive functional study or reversible changes in the electrocardiogram (ECG) consistent with ischemia
  • Patients with signed informed consent
  • Lesion and stent length for ACS and DM subgroup : Length of single lesion < 24 mm and, Summation of total length of all inserted DES in 3 vessel < 60 mm
  • Lesion and stent length for ACS and DM subgroup : Length of single lesion < 24 mm and, Summation of total length of all inserted DES in 3 vessel < 60 mm
  • Lesion and stent length for long lesion subgroup : Length of single stent per single lesion > 28 mm and, Summation of total length of all inserted DES in 3 vessel ≤ 90 mm, Possible overlapping stent
  • Lesion and stent length for short lesion subgroup : Length of single lesion < 24 mm and, Summation of total length of all inserted DES in 3 vessel < 60 mm
  • Significant coronary artery stenosis (>50% by visual estimate) considered for coronary revascularization with stent implantation
  • Reference vessel diameter of 2.5 to 4.0 mm by operator assessment
  • Lesion success (30% or less residual stenosis by visual assessment over the entire stent length, with TIMI-3 flow and no more than an NHLBI type B peri-stent dissection

排除标准

  • Contraindication to anti-platelet agents & bleeding history within prior 3 months
  • Known hypersensitivity or contraindication to any of the following medications: Heparin, Aspirin, Clopidogrel, limus related drug
  • Prior history of the following presentations : Cerebral vascular accident (not including transient ischemic attack, Peripheral artery occlusive diseases, Thromboembolic disease, Stent thrombosis
  • Severe hepatic dysfunction (3 times normal reference values)
  • Significant renal dysfunction (Serum creatinine > 2.0 mg/dl)
  • Significant leukopenia, neutropenia, thrombocytopenia, anemia, or known bleeding diathesis
  • Cardiogenic shock
  • LVEF < 40%
  • Pregnant women or women with potential childbearing
  • Life expectancy 3 year
  • Overlapped DESs(only long lesion subgroup is possible overlapping)
  • Left main disease requiring PCI
  • Bifurcation lesion with 2-stent technique
  • Target lesions with in-stent restenosis at the stented segment of DES or BMS
  • Lesions with chronic total occlusion
  • History of PCI with DES
  • In-stent restenosis lesion

研究组 & 干预措施

Endeavor resolute arm

Active Comparator

干预措施: Zotarolimus-eluting stent for ACS and DM (Device)

Xience arm

Active Comparator

干预措施: Everolimus-eluting stent for long lesion (Device)

Cypher arm

Active Comparator

干预措施: Sirolimus-eluting stent for short lesion (Device)

Endeavor arm

Experimental

干预措施: Zotarolimus-eluting stent (Device)

结局指标

主要结局

Primary Outcome The composite of cardio-vascular death, MI, stent thrombosis, TVR and bleeding (minor or major) following randomly assigned DES implantation

时间窗: 12 months after stent implantation

次要结局

未报告次要终点

研究者

申办方类型
Other
责任方
Sponsor

研究点 (2)

Loading locations...

相似试验