A Novel Fluorescent Ductal Needle With Controllable Detachment for Real-time Localization and Sampling of High-risk Breast Micro Lesions: a Retrospective Study

The Fourth Affiliated Hospital of China Medical University1 个研究点 分布在 1 个国家目标入组 300 人开始时间: 2025年6月1日最近更新:
干预措施

试验速览

阶段
不适用
状态
招募中
入组人数
300
试验地点
1
主要终点
pathological assessment concordance rates

研究概览

简要总结

This retrospective cohort study investigates the differences in the reliability of rapid pathology compared to postoperative pathology when utilizing a novel fluorescent localization needle equipped with a controllable shedding quantum dot chiral nanofluorescent coating, in contrast to traditional localization techniques for breast duct lesions. The primary goal is to evaluate the clinical effectiveness of this innovative fluorescent localization needle in facilitating accurate pathological diagnoses of micro lesions situated within breast ducts.

详细描述

The diameter of breast ducts is less than 0.7 mm, which poses a considerable technical challenge in the accurate localization of early-stage small lesions during surgical and pathological sampling. These early micro lesions typically measure on the millimeter scale, necessitating an increased excision margin by surgeons to reduce the risk of overlooking them. However, this practice complicates the pathologists' ability to accurately identify these micro lesions during diagnosis, thereby heightening the likelihood of missed diagnoses and the potential for additional surgeries for patients. Current localization methods, such as liquid methylene blue and traditional localization needles, demonstrate a high rate of pathological missed diagnoses due to inaccuracies in localization and specimen contamination. Therefore, there is an urgent need for the development of innovative localization technologies that can facilitate the precise identification of millimeter-scale micro lesions within breast ducts and improve the accuracy of pathological sampling. This study aims to conduct a retrospective analysis to compare the consistency of intraoperative and postoperative pathological assessments between a novel fluorescent localization needle, which features a controllable shedding quantum dot chiral nanofluorescent coating, and conventional localization techniques used during breast duct lesion surgeries. The objective is to evaluate the clinical utility of the new fluorescent localization needle in the accurate pathological diagnosis of micro lesions within breast ducts and to enhance the precision of pathological assessments.

研究设计

研究类型
Observational
观察模型
Cohort
时间视角
Retrospective

入排标准

年龄范围
18 Years 至 75 Years(Adult, Older Adult)
性别
Female
接受健康志愿者

入选标准

  • Female patients aged 18-75 years.
  • Patients who have been diagnosed intraductal breast lesion by ductoscopy.
  • Patients who have undergone ductal excision.

排除标准

  • Pregnant or breastfeeding.
  • Patients who have known allergy to quantum-dot materials or localization needle components.
  • Patients with active hepatitis B or C infection with detectable viral load.
  • Patients with unstable cardiovascular disease (e.g., recent myocardial infarction, uncontrolled arrhythmia, NYHA class III-IV heart failure).
  • Patients with history of neurological or psychiatric disorders that may impair compliance (e.g., epilepsy, dementia).
  • Patients with incomplete clinical data.
  • Patients who concurrent participation in another interventional clinical trial.

研究组 & 干预措施

Experimental

Patients received breast ductal excision surgery utilizing a novel fluorescent localization marker needle. Specimens were submitted for intraoperative frozen section analysis as well as for postoperative paraffin-embedded pathological evaluation.

干预措施: novel fluorescent localization marker needle (Device)

Control

Patients received breast ductal excision surgery utilizing conventional localization methods. Specimens were submitted for intraoperative frozen section analysis as well as for postoperative paraffin-embedded pathological evaluation.

干预措施: conventional localization marker needle (Device)

结局指标

主要结局

pathological assessment concordance rates

时间窗: Data analysis period: June 2025- December 2025

Evaluate and compare the discrepancies in the consistency of intraoperative frozen and postoperative paraffin-embedded pathological assessments between subjects undergoing breast duct excision surgery utilizing a novel fluorescent localization marker needle and those employing conventional localization methods.

次要结局

未报告次要终点

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

JIAN WEN

Deputy Director of the Fifth General Surgery Department

The Fourth Affiliated Hospital of China Medical University