Use of MENSA to Improve the Diagnosis of Causative Infectious Agent and Monitor Infection Recovery in Orthopedic Spine Infection
试验速览
- 阶段
- 不适用
- 状态
- Enrolling By Invitation
- 入组人数
- 200
- 试验地点
- 1
- 主要终点
- The percentage of Staphylococcus aureus spine implant associated infections correctly identified by "medium enriched for newly synthesized antibodies" (MENSA)
研究概览
简要总结
The goal of this study is to test a new way to diagnose and track treatment of spine infections caused by the bacteria Staphylococcus aureus.
详细描述
Ongoing Staphylococcus aureus (S. aureus) infections of the spine associated with orthopedic hardware implants elicit prominent immune responses against a repertoire of proteins characteristic of the invading pathogen. Antibodies specific for these antigens can be measured in the serum or in a novel sample created by culturing circulating Antibody Secreting Cells (ASC) in vitro where they create an analytic fluid called here "medium enriched for newly synthesized antibodies" (MENSA). The hypothesis of this study addresses three essential attributes of this analytic approach that can yield both a valuable tool for research on spinal infections and in the future, this can be developed a clinical tool for diagnosis and monitoring of therapeutic success in patients. By measuring the emergence of these signature antibodies in the serum and/or MENSA, the goals of this study are: 1) To differentiate between patients with an ongoing S. aureus infections, not just "general infection, in the spine using only blood samples; 2) To track the success (or failure) of therapeutic interventions; and 3) to distinguish spinal infections from S. aureus infections in other sites by the repertoire of antibodies that are elicited.
研究设计
- 研究类型
- Observational
- 观察模型
- Cohort
- 时间视角
- Prospective
入排标准
- 年龄范围
- 18 Years 至 85 Years(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •patients with known or suspected spinal infections associated with spinal orthopedic implant(s);
- •patients over 18 years of age and younger than 85;
- •patients undergoing spinal revision surgery.
排除标准
- •Diagnosed as immuno-compromised or immuno-suppressed based on medication use;
- •On-going or previously diagnosed musculoskeletal infections associated non-spine hardware (e.g., prosthetic hip, prosthetic knee, prosthetic shoulder);
- •Current diabetic foot ulcer/infection;
- •Patients undergoing cancer treatment (including radiation and chemotherapies);
- •Pregnancy;
- •Absence of a spleen;
- •Over the age of 85 or under the age of
- •Weigh less than 110 pounds, or for which it would otherwise be unsafe for them to undergo a blood draw.
结局指标
主要结局
The percentage of Staphylococcus aureus spine implant associated infections correctly identified by "medium enriched for newly synthesized antibodies" (MENSA)
时间窗: Baseline
"A medium enriched for newly synthesized antibodies" (MENSA) is the supernatant collected from cultured antibody secreting cells. Peripheral blood monocytes (PBMCs) are washed and placed into cell culture. After 24 hours, the media contains a high concentration of newly made antibodies. This media is referred to as MENSA. This is tested to see if the antibodies collected react against a panel of antigens. MENSA immunoglobulin G (IgG) titers for each antigen will be assessed for their predictive ability to identify the presence of S. aureus in spine implant-associated infections using receiver operating characteristic (ROC) curve analysis (alone or in combination), with overall prediction accuracy summarized by the area-under-the-curve (AUC). Participants will then be categorized as Staphylococcus aureus (S. aureus) positive or negative based on MENSA. The percentage of correctly identified S. aureus determinations compared to clinical diagnosis will be determined.
Change "Medium enriched for newly synthesized antibodies" (MENSA) titers in the post-operative period
时间窗: 2 weeks, 6 weeks, 3 months, 6 months, 1 year and 2 years post-surgery
MENSA IgG titers (as defined in Outcome 1) will be measured at 2 weeks, 6 weeks, 3 months, 6 months, 1 year and 2 years post-surgery. A longitudinal measure of antibody activity defined as the average change per study visit from baseline will used to track infection clearance versus persistent infection. Levels of anti-S. aureus antibodies in MENSA should decline to background in patients whose infections have been successfully treated and remain elevated in those whose infections persist.
"Medium enriched for newly synthesized antibodies" (MENSA) titers in spine implant infections compared to S. aureus infections of other orthopedic site infections.
时间窗: Baseline
MENSA IgG titers (as defined in Outcome 1) will be compared to responses measured in a pre-existing collection of samples from patients who had experienced: 1) prosthetic joint infections; 2) septic arthritis; 3) diabetic foot infections; 4) soft-tissue infections; and 5) fracture-related infections. The goal will be to identify a combination of antigens that is uniquely discriminatory for spine infections.
次要结局
- Confirmation of Staphylococcus aureus in spine implant associated infection by polymerase chain reaction (PCR)(Baseline)
