跳至主要内容
临床试验/NCT06058650
NCT06058650招募中不适用

Pilot Clinical Study to Evaluate Molecular Breast Imaging- Guidance for Sampling of Breast Abnormalities

Mayo Clinic1 个研究点 分布在 1 个国家目标入组 70 人开始时间: 2021年8月26日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
招募中
发起方
Mayo Clinic
入组人数
70
试验地点
1
主要终点
Change in image of lesion

研究概览

简要总结

This clinical trial tests how well molecular breast imaging (MBI) works to guide the collection of a breast biopsy in patients with a breast abnormality. Currently, a biopsy is often guided by either ultrasound or mammography in order to ensure that a sample of the correct part of the breast is taken. Sometimes a lesion or part of the lesion cannot be seen on ultrasound or mammography, and, therefore, a biopsy guided with ultrasound or mammography may not be always be accurate. Studies have shown that high resolution MBI may have potential to improve the detection of some breast tumors. This trial uses a new high-resolution MBI system that may help perform a biopsy using MBI.

详细描述

PRIMARY OBJECTIVE:

I. To evaluate a methodology for MBI-guided biopsy of suspicious breast lesions.

OUTLINE: Patients are assigned to 1 of 2 study parts.

PART I: Patients receive technetium Tc-99m sestamibi intravenously (IV) and undergo MBI on study.

PART II: Patients receive technetium Tc-99m sestamibi IV and undergo MBI. Patients whose breast lesions of interest are visualized on MBI then undergo breast biopsy using the Stereo Navigator accessory.

研究设计

研究类型
Interventional
分配方式
Non Randomized
干预模型
Sequential
主要目的
Diagnostic
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
Female
接受健康志愿者
否

入选标准

  • •PART I: Women aged 18 years or older
  • •PART I: If able to become pregnant, negative pregnancy test within 48 hours prior to MBI biopsy procedure
  • •PART I: Individuals who have previously (within the last 3 years) undergo an MBI study and were found to have at least one breast imaging finding on MBI that was subsequently shown (through additional imaging, biopsy or follow-up) to be benign in nature
  • •PART I: Individuals who have agreed to participate in the study and who have signed the study-specific informed consent
  • •PART II: Women aged 18 years or older
  • •PART II: If able to become pregnant, negative pregnancy test within 48 hours prior to MBI biopsy procedure
  • •PART II: Individuals who have previously (within the last 3 years) undergone an MBI study and were found to have at least one breast imaging finding on MBI that was subsequently shown (through additional imaging, biopsy or follow-up) to be benign or probably benign in nature
  • •PART II: Individuals who had recent conventional imaging work-up including either x-ray mammography, ultrasound, MBI, or MRI of the breast and are found to have at least one breast imaging finding for which biopsy is required or recommended, specifically:
  • •Individuals who have a breast abnormality(ies) on imaging with mammography, ultrasound, MBI, or MRI (as per American College of Radiology [ACR] Breast Imaging Reporting and Data System [BIRADS] 3, or higher) and requiring imaging follow-up or biopsy confirmation
  • •PART II: Individuals who have agreed to participate in the study and who have signed study-specific informed consent

排除标准

  • •PART I: Women who are pregnant
  • •PART I: Women who are currently lactating or discontinued breastfeeding < 2 months prior to the study
  • •PART I: Age less than 18 years
  • •PART I: Women with breast implant(s) in the breast containing the lesion of interest
  • •PART I: Inability to provide informed consent
  • •PART II: Women who are pregnant
  • •PART II: Women who are currently lactating or discontinued breastfeeding < 2 months prior to the study
  • •PART II: Age less than 18 years
  • •PART II: Women with breast implant(s) in the breast containing the lesion of interest
  • •PART II: Women who have recently (within the last 3 months) undergone biopsy of the breast finding
  • •PART II: Women who are scheduled for a sentinel node procedure using radioactive Tc-99m within 24 hours of MBI-guided biopsy
  • •PART II: Patients with contraindications for core biopsy and other invasive procedures such as blood coagulation disorders, infection, or who are unwilling to discontinue use of anticoagulant medication prior to the procedure
  • •PART II: Inability to provide informed consent
  • •PART II: Women who have had surgery on the study breast(s) within the past 12 months

研究组 & 干预措施

Part I (technetium Tc-99m sestamibi, MBI)

Experimental

Patients receive technetium Tc-99m sestamibi IV and undergo MBI on study.

干预措施: Scintimammography (Radiation)

Part II (technetium Tc-99m sestamibi, MBI, biopsy)

Experimental

Patients receive technetium Tc-99m sestamibi IV and undergo MBI. Patients whose breast lesions of interest are visualized on MBI then undergo breast biopsy using the Stereo Navigator accessory.

干预措施: Medical Device Usage and Evaluation (Other)

Part II (technetium Tc-99m sestamibi, MBI, biopsy)

Experimental

Patients receive technetium Tc-99m sestamibi IV and undergo MBI. Patients whose breast lesions of interest are visualized on MBI then undergo breast biopsy using the Stereo Navigator accessory.

干预措施: Biopsy of Breast (Procedure)

Part II (technetium Tc-99m sestamibi, MBI, biopsy)

Experimental

Patients receive technetium Tc-99m sestamibi IV and undergo MBI. Patients whose breast lesions of interest are visualized on MBI then undergo breast biopsy using the Stereo Navigator accessory.

干预措施: Scintimammography (Radiation)

Part I (technetium Tc-99m sestamibi, MBI)

Experimental

Patients receive technetium Tc-99m sestamibi IV and undergo MBI on study.

干预措施: Technetium Tc-99m Sestamibi (Other)

Part II (technetium Tc-99m sestamibi, MBI, biopsy)

Experimental

Patients receive technetium Tc-99m sestamibi IV and undergo MBI. Patients whose breast lesions of interest are visualized on MBI then undergo breast biopsy using the Stereo Navigator accessory.

干预措施: Technetium Tc-99m Sestamibi (Other)

结局指标

主要结局

Change in image of lesion

时间窗: Baseline; Up to 6 months

The coordinates of the lesion of interest on the high resolution MBI image will be recorded. The guidance procedure will be considered successful if 1) the pre and post images of the lesion demonstrated one of the following: decreased in size, central or eccentric defect where sampled, or decrease in intensity, or 2) pathology results demonstrate malignancy or a specific benign concordant result.

Accuracy of depth estimation by difference in apparent lesion size

时间窗: Baseline; Up to 6 months

For each patient in whom pathology confirms successful sampling of the lesion seen on MBI, the error in depth estimation will be calculated as the average error for each depth estimation method from all core biopsy samples. This will allow comparison of the accuracy of the 3 different depth estimation methods and potentially provide further information on the strengths and weakness of each of the three methods for depth estimation. Uniformity activity along the entire 20 mm core would indicate failure to biopsy the lesion. Any portion of increased uptake will be noted and the center of activity will be determined relative to the mid-point of the core sample. This distance will be recorded as the difference between estimated depth and true depth.

Accuracy of depth estimation by difference in attenuation from opposing views

时间窗: Baseline; Up to 6 months

For each patient in whom pathology confirms successful sampling of the lesion seen on high-resolution molecular breast imaging (MBI), the error in depth estimation will be calculated as the average error for each depth estimation method from all core biopsy samples. This will allow comparison of the accuracy of the 3 different depth estimation methods and potentially provide further information on the strengths and weakness of each of the three methods for depth estimation. Uniformity activity along the entire 20 mm core would indicate failure to biopsy the lesion. Any portion of increased uptake will be noted and the center of activity will be determined relative to the mid-point of the core sample. This distance will be recorded as the difference between estimated depth and true depth.

Validation of timeframe

时间窗: Baseline

Time from injection of the technetium Tc-99m sestamibi to identification of the appropriate needle guide hole will be reviewed to determine if and where any improvements in workflow can be made to reduce the overall procedure time for patients.

Accuracy of depth estimation by triangulation

时间窗: Baseline; Up to 6 months

For each patient in whom pathology confirms successful sampling of the lesion seen on MBI, the error in depth estimation will be calculated as the average error for each depth estimation method from all core biopsy samples. This will allow comparison of the accuracy of the 3 different depth estimation methods and potentially provide further information on the strengths and weakness of each of the three methods for depth estimation. Uniformity activity along the entire 20 mm core would indicate failure to biopsy the lesion. Any portion of increased uptake will be noted and the center of activity will be determined relative to the mid-point of the core sample. This distance will be recorded as the difference between estimated depth and true depth.

次要结局

未报告次要终点

研究者

发起方
Mayo Clinic
申办方类型
Other
责任方
Sponsor

研究点 (1)

Loading locations...

相似试验