跳至主要内容
临床试验/NCT05758506
NCT05758506已完成不适用

Developing a Screening Tool for Primary Immunodeficiency Disease (PID) in Pakistan

PATH1 个研究点 分布在 1 个国家目标入组 200 人开始时间: 2024年7月1日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
200
试验地点
1
主要终点
Diagnostic accuracy

研究概览

简要总结

Case-control diagnostic accuracy study with 130 potential pediatric PID+ (primary immunodeficiency) patients, and 100 age-matched, healthy controls (PID-). The potential PID+ participants will be recruited prospectively through 9 hospitals in Sindh and Punjab states or contacted via the PID surveillance registry developed by AKU Hospital's Polio Excretion in PID study to identify children with primary antibody deficiency (PAD+: a type of PID+); healthy, age-matched PID-participants will be recruited by snowball sampling. At the point of care, health care workers (HCWs) will collect capillary blood samples (0.1mL) to run the PID rapid screening test and reader on potential PID+ participants (identified by exhibiting >2 of the Jeffrey Modell warning signs) and healthy, age-matched controls. All pediatric study participants will be sent to the hospital lab to have a confirmatory immunology panel (see 4.4.1 Diagnosing PID for the battery of tests) run on a serum/plasma sample to confirm their PID diagnosis (PID+/PAD-, PID+/PAD+, PID-); a 1.5uL aliquot of serum/plasma will simultaneously be used to run a PID rapid screening test by a laboratory technician (LT). HCWs and LTs will be blinded to true PID status. Blood and serum PID rapid screening test results will be compared to the confirmatory immunology panel to determine diagnostic accuracy. All clinical management of study participants will follow the standard of care for PID in Pakistan and will be based upon the immunology panel result. The HCWs and LTs administering the tests will be trained prior to the diagnostic accuracy test (see Objectives below) and will provide feedback on the tool post-training and post-use to assess usability, acceptability, and feasibility of integrating the test and digital reader into tertiary hospitals for the purpose of improved national PID surveillance, improved PID patient care, and polio eradication in Pakistan.

研究设计

研究类型
Observational
观察模型
Cohort
时间视角
Prospective

入排标准

年龄范围
3 Months 至 15 Years(Child)
性别
All
接受健康志愿者

入选标准

  • Aged 3 months to 15 years
  • Presents for care at 1 of 9tertiary hospitals participating in the study
  • Potential PID+ (Case): Child is identified by HCW to have >2 Jeffrey Model warning signs of PID. [Note: Upon immunology panel testing, this group will be separated into three categories: PID-, PID+, and PID+/PAD+ meaning they have 1 of 5 relevant primary antibody deficiencies (PAD+)].
  • PID-(Control): Child is identified (by snowball sampling) as being in good health, and having the same age (within 12 months) as another child who produced a PID+ result.
  • Caregiver consents to participate in the study and provides informed consent. If their children are 10 years of age or older, that child must also give assent.

排除标准

  • Aged less than 3 months or greater than 15 years of age
  • Caregiver does not consent to participate, or child >10years does not give assent to participate.
  • Having received IVIG in the past 90 days

结局指标

主要结局

Diagnostic accuracy

时间窗: 8 month

Estimates of diagnostic accuracy characteristics with 95% confidence intervals (sensitivity, specificity, PPV, NPV) of the PID screening test for relevant PIDs in a Pakistani population of both PID+ children and PID- age-matched healthy controls

Determine usability, acceptability, feasibility of integrating PID test and digital reader into tertiary hospitals for improved patient care

时间窗: 8 months

Estimates of user effectiveness, efficacy, satisfaction, learnability, and feasibility among trained health care workers (HCWs) and laboratory technicians (LTs) will be evaluated using observation checklists and surveys. The observation checklist will evaluate the ability to administer the test, read the test results accurately after the appropriate amount of waiting time, record the result in the digital reader app, operate the digital app to read a photograph of the test result, and their ease of performing these tasks. This methodology adheres to ISO 9241-210 on human-centered design principles in usability testing.

次要结局

  • Effectiveness - agreement between the PID screening test readouts (#1, #2) with each other, the digital reading, a PATH expert panel, and the local PID standard of care immunology tests.(8 months)
  • Effectiveness(8 months)
  • Understandability of diagnostic instruction(8 months)
  • Usability of screening test result outputs(8 months)
  • Usability for facilitators(8 months)

研究者

发起方
PATH
申办方类型
Other
责任方
Principal Investigator
主要研究者

Megan Parker

Senior Research Research Officer, Diagnostics

PATH

研究点 (1)

Loading locations...