跳至主要内容
临床试验/NCT02092428
NCT02092428已完成1 期

Contrast- Enhanced Whole-Heart Coronary Magnetic Resonance Angiography (MRA) at 3.0T

Cedars-Sinai Medical Center1 个研究点 分布在 1 个国家目标入组 333 人开始时间: 2011年4月1日最近更新:
适应症
干预措施

试验速览

阶段
1 期
状态
已完成
入组人数
333
试验地点
1
主要终点
Diagnostic performance of 3.0-T contrast-enhanced whole-heart coronary MRA in patients with suspected coronary artery disease (CAD)

研究概览

简要总结

Investigators at the Biomedical Imaging Research Institute (BIRI) at Cedars-Sinai Medical Center have developed a Magnetic Resonance Imaging (MRI) method for imaging coronary arteries using slow-infusion, contrast-enhanced data acquisition. This method allows faster data acquisition and better spatial resolution.

Specific aims of this study are to:

  1. compare coronary artery imaging with and without contrast media on both healthy subjects and patients;
  2. assess the accuracy of coronary MRI in detecting coronary artery disease as compared to conventional x-ray angiography

Researchers hypothesize that contrast-enhanced MRI will improve the delineation of coronary arteries over non-contrast-enhanced MRI and that optimized, contrast-enhanced coronary MRI technique will accurately detect coronary artery disease (CAD) as compared to conventional x-ray angiography.

详细描述

This is a study to compare image quality between contrast and non-contrast cardiac MR and to evaluate the diagnostic accuracy of a cardiac MRI procedure in a patient population that includes both healthy volunteers and a study group of patients with known CAD who are scheduled for clinical coronary angiography within one month of signing informed consent. Both groups are eligible for a combination of imaging tests. Subjects may receive either a non-contrast MRI or a contrast-enhanced MRI depending upon their kidney function and study focus. Also based upon the focus of the study at the time of the scan and to improve image quality, a beta-blocker to lessen motion artifact in patients with higher heart rates may be administered or patients may be asked to undergo a stress test for comparison.This is a one-day research procedure. Studies are acquired from the approved Institutional Review Board #25881 Cedars-Sinai Biomedical Imaging Research Registry.

研究设计

研究类型
Interventional
分配方式
Non Randomized
干预模型
Parallel
主要目的
Diagnostic
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者
是

入选标准

  • •All subjects must be enrolled in the IRB approved Cedars-Sinai Biomedical Imaging Research Registry where data is collected for this analysis study.
  • •Male or female ≥ 18years of age
  • •Healthy Group -No known CAD
  • •CAD Group-Scheduled for clinical invasive coronary artery x-ray angiography within one month of study participation

排除标准

  • •MR imaging is contraindicated in persons with mechanically, magnetically, or electrically activated implants, such as cardiac pacemakers, neurostimulators, and infusion pumps.
  • •Persons with ferromagnetic implants and ferromagnetic foreign bodies, such as intracranial, aneurysm clips, shrapnel and intraocular metal chips as these could become dislodged.
  • •Patients who are pregnant, nursing are implanted with intrauterine devices (IUD's)
  • •Persons who are in atrial fibrillation at the time of the MR scan as this could result in poor image quality due to interference with electrocardiographic gating necessary for image acquisition.
  • •Persons unable to tolerate MRI imaging secondary to an inability to lie supine or severe claustrophobia.
  • •Patient with renal failure (GFR< 45)
  • •Allergy to animal dander or animal-instigated asthma
  • •Specific to Ablavar: Baseline ECG measurements and concomitant medications will be checked on subjects who are chosen to participate in the Ablavar study, based upon study needs. If the ECG measurements and/or medications indicate that the subject is at high risk for arrhythmia, the subject will be excluded from the Ablavar study, but can participate in the OptiMark/MultiHance contrast study or non-contrast study.
  • •Specific to beta-blocker administration: no contraindication to beta blockers. If the subject is found to have a contraindication to beta-blockers or declines the administration of beta-blockers the subject will be excluded from the beta-blocker portion but can still participate in a non-contrast or contrast-enhanced scan without beta-blocker administration.
  • •Specific to Regadenoson: no contraindication to regadenoson administration. If the subject is found to have a contraindication to regadenoson the subject will be excluded from the regadenoson portion but can still participate in a non-contrast or contrast-enhanced scan without regadenoson stress testing.
  • •Specific to Adenosine: no contraindication to adenosine administration.If the subject is found to have a contraindication to adenosine the subject will be excluded from the adenosine portion but can still participate in a non-contrast or contrast-enhanced scan without adenosine stress testing.

研究组 & 干预措施

Image Quality

Experimental

Healthy volunteers and patients will undergo non-contrast MRI or contrast-enhanced MRI to compare image quality between contrast and non-contrast scans.

干预措施: Image Quality (Other)

Diagnostic Accuracy

Experimental

Healthy volunteers and patients will undergo non-contrast MRI or contrast-enhanced MRI to assess the diagnostic accuracy of coronary MRI in detecting CAD as compared to conventional x-ray angiography

干预措施: Diagnostic Accuracy (Other)

结局指标

主要结局

Diagnostic performance of 3.0-T contrast-enhanced whole-heart coronary MRA in patients with suspected coronary artery disease (CAD)

时间窗: one day

sensitivity and specificity

次要结局

未报告次要终点

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Debiao Li, PhD

Director, Biomedical Imaging Research Institute

Cedars-Sinai Medical Center

研究点 (1)

Loading locations...