跳至主要内容
临床试验/NCT06518681
NCT06518681Enrolling By Invitation不适用

Prospective Clinical Trial Evaluating the Safety and Efficacy of Prosthetic Polymer Heart Valves for the Treatment of Aortic Valve Disease

Suzhou Hearthill Medical Technology Co.,LTD1 个研究点 分布在 1 个国家目标入组 10 人开始时间: 2024年8月15日最近更新:
适应症

试验速览

阶段
不适用
状态
Enrolling By Invitation
发起方
入组人数
10
试验地点
1
主要终点
Compliance rate of prosthetic valve function

研究概览

简要总结

The purpose of this study is to conduct the initial clinical investigation of the HeartHill Medical's polymer aortic valve, namely PoliaVavle,to collect evidence on the device's safety and performance.

详细描述

The polymer aortic valve, PoliaValve, from HeartHIll Medical, is indicated as a replacement for patients with severe aortic valve disease, including severe aortic stenosis, severe aortic regurgitation, or both. These patients will be included in the study after systematic assessment that the subjects meet the criteria for inclusion in the study.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Treatment
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Subjects must meet all the following conditions:
  • Subjects are ≥60 years old;
  • The subjects understand the nature and purpose of the research, voluntarily participate and sign the informed consent form, comply with the trial requirements, are willing to cooperate with surgical treatment and follow-up, and agree to relevant follow-up interviews and examinations;
  • The subject is diagnosed with severe aortic stenosis and/or regurgitation (or insufficiency) through echocardiography;
  • According to the 2020 ACC/AHA management guidelines for patients with valvular heart disease, the subject meets the indications for aortic valve replacement surgery and the preoperative assessment recommends surgical aortic valve replacement.

排除标准

  • Subjects must not meet any of the following conditions:
  • Other valve diseases with indications for surgery, such as severe mitral regurgitation, severe tricuspid regurgitation, moderate or above mitral stenosis, etc. require combined valve replacement, or had aortic valve surgery in the past;
  • Other serious cardiovascular diseases with indications for surgery, such as Stanford type A aortic dissection, aortic sinus aneurysm (sinus diameter >5.0cm), hypertrophic obstructive cardiomyopathy, diffuse three-vessel coronary artery disease , end-stage heart failure while simultaneously placing a left ventricular assist device, etc.;
  • End-stage heart failure that is expected to be irreversible by aortic valve surgery, such as severe left ventricular dysfunction with LVEF <25%, or severe heart failure that cannot be corrected, or severe pulmonary hypertension assessed by right heart catheterization, predict postoperative plans Perform Impella, IABP or left ventricular assist within the hospital;
  • Decompensated heart failure, cardiogenic shock, malignant arrhythmia, etc. that require mechanical circulatory assistance, mechanical ventilation or emergency surgery before surgery;
  • Active endocarditis or vegetations on the heart within 3 months;
  • History of severe acute myocardial infarction or cerebrovascular accident within 3 months (excluding lacunar infarction);
  • Those with severe renal insufficiency (GFR <30mL/min) or end-stage renal disease requiring long-term dialysis;
  • Liver dysfunction or gastrointestinal dystrophy;
  • Patients with active bleeding, bleeding tendency or unable to receive anticoagulation treatment;
  • Those with severe ventilation or ventilatory dysfunction who require continuous oxygen therapy;
  • Those who have poor compliance or cognitive impairment (such as coma, Parkinson's disease, Alzheimer's disease, drug abuse), are unable to comply with requirements or refuse to cooperate in completing study follow-up visits;
  • Other reasons causing life expectancy to be less than 1 year, such as malignant tumors and immunodeficiency diseases;
  • Other situations in which patients are not suitable for artificial aortic valve replacement or are not suitable to participate in this trial.

结局指标

主要结局

Compliance rate of prosthetic valve function

时间窗: 1 month following patient enrollment completion

The compliance rate of prosthetic valve function evaluation at 1 month after surgery. The standard of prosthetic valve function is as follows: prosthetic valve pressure difference \<20mmHg or peak flow rate \< 3m/s, no moderate or above intravalvular regurgitation or paravalvular leakage), and no reintervention is required.

Surgery success rate

时间窗: 1 month following patient enrollment completion

Event-free survival of the prosthetic valve at 1 month postoperatively. Prosthetic valve degeneration includes stenosis and/or regurgitation due to structural abnormalities of the valve itself (e.g., leaflet tears, detachment, calcification, fibrosis, deformation of the valve frame, and fracture of the material of the connecting parts between the valve components) (referred to as structural valve degeneration), as well as dysfunction due to infective endocarditis, perivalvular leakage, valve prosthesis-patient mismatch, valve displacement, and leaflet thrombosis (referred to as nonstructural valve degeneration). Prosthetic valve degeneration usually consists of three stages, with the first stage consisting of morphological evidence of valve degeneration and structural abnormalities, before significant hemodynamic changes are evident.

次要结局

  • EOA(baseline and 1 month, 6months, 12months following patient enrollment completion)
  • Mean transvalvular pressure difference(baseline and 1 month, 6months, 12months following patient enrollment completion)
  • Peak flow velocity(baseline and 1 month, 6months, 12months following patient enrollment completion)
  • Regurgitation(baseline and 1 month, 6months, 12months following patient enrollment completion)
  • New York Heart Association Assessment (NYHA)(baseline and 1 month, 6months, 12months following patient enrollment completion)
  • BNP or NT-proBNP(baseline and 1 month, 12months following patient enrollment completion)

研究者

发起方
Suzhou Hearthill Medical Technology Co.,LTD
申办方类型
Industry
责任方
Sponsor

研究点 (1)

Loading locations...