跳至主要内容
临床试验/NCT02921594
NCT02921594撤回不适用

Comparison of Vanguard XP and Vanguard CR Total Knee Arthroplasties: A Cross Sectional Pilot Study Evaluating Intraarticular Kinematics and Standing Balance by Dynamic Fluoroscopy and Force Plate Examination

Hvidovre University Hospital2 个研究点 分布在 1 个国家开始时间: 2016年9月最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
撤回
试验地点
2
主要终点
Anterior-posterior translation of the femoral component with respect to the tibia component

研究概览

简要总结

Primary: The primary objective of this pilot study is to compare the intraarticular kinematics by fluoroscopy of Vanguard XP to that of Vanguard CR.

Secondary: The secondary objective of this pilot study is to compare the standing balance by force plate of patients with the Vanguard XP prosthesis to those who have Vanguard CR prosthesis. Furthermore, we wish to assess isometric quadriceps muscle strength in both groups.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Treatment
盲法
Single (Participant)

入排标准

年龄范围
18 Years 至 75 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Participant in the XP vs. CR study (inherited traits from study inclusion)
  • Overall healthy. Have attended standard physiotherapy after unilateral total knee replacement
  • Are able to perform the tasks
  • Excellent clinical scores (Oxford Knee Score above 39 at 1 year follow up)

排除标准

  • Knee pain above 20 on a 0-100 visual analogue scale
  • Any clinical relevant pain from adjacent joints
  • Active Knee flexion below 100
  • Signs of implant migration, loosening, and implant mal-alignment

研究组 & 干预措施

Total knee arthroplasty with Vanguard XP

Active Comparator

The new Vanguard XP Total knee arthroplasty system is a further development of the Vanguard TKA. The new Vanguard XP system both cruciate ligaments are preserved.

干预措施: Total knee arthroplasty with Vanguard XP (Device)

Total knee arthroplasty with Vanguard XP

Active Comparator

The new Vanguard XP Total knee arthroplasty system is a further development of the Vanguard TKA. The new Vanguard XP system both cruciate ligaments are preserved.

干预措施: Total knee arthroplasty with Vanguard CR (Device)

Total knee arthroplasty with Vanguard CR

Active Comparator

Total knee arthroplasty system without preservation of the anterior cruciate ligament

干预措施: Total knee arthroplasty with Vanguard XP (Device)

Total knee arthroplasty with Vanguard CR

Active Comparator

Total knee arthroplasty system without preservation of the anterior cruciate ligament

干预措施: Total knee arthroplasty with Vanguard CR (Device)

结局指标

主要结局

Anterior-posterior translation of the femoral component with respect to the tibia component

时间窗: at least one year post surgery

Group mean in millimeters (mm)

Axial rotation of the femoral component with respect to the tibia component

时间窗: at least one year post surgery

Group mean in degrees (°)

次要结局

  • Velocity of center of pressure(at least one year post surgery)
  • Isometric quadriceps muscle strength(at least one year post surgery)
  • Rambling-trembling distance(at least one year post surgery)
  • Traveled distance of center of pressure(at least one year post surgery)

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Anders Troelsen

Professor, MD, PhD, dr.med

Hvidovre University Hospital

研究点 (2)

Loading locations...

相似试验