跳至主要内容
临床试验/NCT03803098
NCT03803098Unknown不适用

Evaluation of the Metrological Reliability of Connected Objects Available to the Public in the Measurement of Medical Physiological Parameters

Assistance Publique - Hôpitaux de Paris1 个研究点 分布在 1 个国家目标入组 400 人开始时间: 2019年2月12日最近更新:
适应症

试验速览

阶段
不适用
入组人数
400
试验地点
1
主要终点
relative error between the gold-standard measure of the physiological parameter and the corresponding measure with the tested device,

研究概览

简要总结

Many connected objects available over-the-counter to the general public claim to measure physical quantities that may have a medical application. Examples include heart rate, oxygen saturation, respiratory rate, blood pressure, body composition between body fat, lean mass and bone mass, and motion analysis. .

The continuous collection of these quantities by a cheap and easily accessible device opens important medical perspectives in the areas of home monitoring of chronic diseases or preventive medicine in general. Nevertheless, the medical decisions that could be made on the basis of the information provided by these objects require that the measurement be reliable, which is not always the case.

The evaluation of the accuracy of measurements made by these objects therefore seems to be a prerequisite for future use in a medical context. This study therefore proposes to test the adequacy between "gold-standard" measurements carried out in consultation in the department of functional explorations of the Bichat Claude-Bernard hospital and the measurements of the same parameters by connected objects, under the conditions of intended uses by their manufacturer.

详细描述

Primary objective : Evaluate, in patients consulting for polysomnography, respiratory functional explorations or osteodensitometry, or as part of a day hospital cardiology. The accuracy of the measurement provided by a connected object in relation to the "gold standard" measurement made during the visit. The parameters studied will be:

  • For polysomnography, pulse oxygen saturation (SpO2), heart rate (HR) and respiratory rate (RF), sleep quality (efficacy, duration of mild slow sleep, deep slow sleep and REM sleep)
  • For bone densitometry, body composition in lean mass, fat mass and bone mass, weight • For respiratory function tests, pulse oxygen saturation (SpO2) and heart rate (HR)
  • For day hospitalization in cardiology, blood pressure (BP), heart rate (HR) and heart rate, existence of rhythm disorders or conduction

Secondary objectives:

  • Evaluate the ease of use of the device (evaluated by an ad-hoc questionnaire completed by the nursing staff)
  • Describe the temporal evolution of the recorded parameters (excluding osteodensitometry for which the measurement is unique)
  • For day hospitalization in cardiology, evaluate the diagnostic performance of objects tested on the existence of cardiac rhythm disorders (sinus bradycardia, sinus tachycardia, atrial fibrillation, presence of extrasystoles) or conduction disorders (atrioventricular block). -ventricular, branch block)

研究设计

研究类型
Observational
观察模型
Other
时间视角
Cross Sectional

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • 未提供

排除标准

  • 未提供

结局指标

主要结局

relative error between the gold-standard measure of the physiological parameter and the corresponding measure with the tested device,

时间窗: the two measures are succesive of the day of the examination

relative error expressed on a percentage

次要结局

  • absolute error between the gold-standard measure of the physiological parameter and the corresponding measure with the tested device,(the two measures are succesive of the day of the examination)

研究者

申办方类型
Other
责任方
Sponsor

研究点 (1)

Loading locations...

相似试验