Development of Bone-vestibular Evoked Myogenic Potential
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 入组人数
- 20
- 试验地点
- 2
- 主要终点
- Vemp response rate
研究概览
简要总结
This study aims to evaluate the effects of different masking conditions on cervical vestibular evoked myogenic potential (cVEMP) responses. Vertical-axis vibrations (VAVs) of 500-Hz short-tone bursts (STB500) and 750-Hz short-tone bursts (STB750) were used to elicit cVEMP responses. These stimuli were delivered through a Mini-Shaker placed at the vertex (Cz) under three masking conditions: no masking (NOM), speech noise masking (SNM), and random interstimulus-interval tone bursts (rISITB). The study focused on testing protocols that can potentially improve unilateral VEMP testing and explore its clinical applicability.
详细描述
Participants and Ethics:
The study recruited 20 healthy adults (10 males and 10 females, aged 20-37 years), all of whom had normal otoscopic findings and no history of hearing issues. Ethical approval was obtained, and all participants provided informed consent.
Bone Conduction Vibrations (BCV):
Bone-conducted vibrations were generated using a SmartEP system and delivered via a Mini-Shaker transducer. Stimuli included 500 Hz and 750 Hz short-tone bursts (STB500 and STB750), calibrated to appropriate levels, with specific rise, plateau, and fall times.
Masking Conditions:
研究设计
- 研究类型
- Interventional
- 分配方式
- Na
- 干预模型
- Single Group
- 主要目的
- Basic Science
- 盲法
- None
入排标准
- 年龄范围
- 20 Years 至 40 Years(Adult)
- 性别
- All
- 接受健康志愿者
- 是
入选标准
- •20y-40y adult
排除标准
- •Having history of hearing loss or dizziness
- •failed hearing screening test
- •Having history of head or neck surgery
结局指标
主要结局
Vemp response rate
时间窗: up to 24 weeks
This study investigates VEMP response rates under different frequencies (500 Hz, 750 Hz) and masking conditions (no masking, speech noise, random tone bursts) to evaluate the effects of masking on VEMP responses.
次要结局
未报告次要终点