Identification of Morphological Characteristics to Predict Difficult Endotracheal Intubation Using a Flexible Fiberscope
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 发起方
- 入组人数
- 420
- 试验地点
- 2
- 主要终点
- Morphologic and morphometric predictors of difficult intubation with the flexible fiberscope.
研究概览
简要总结
This study is designed to identify patients' features predictive of difficult endotracheal intubation using a flexible fiberscope.
详细描述
Endotracheal intubation is an important act in the practice of anesthesiology. Direct laryngoscopy is the most commonly used technique to accomplish this task. Airway characteristics predicting difficult intubation with direct laryngoscopy are well defined. Physical findings, such as Mallampati classification or measurements of the thyromental distance, mouth opening, and neck extension have been validated to help anticipate difficult situations with the direct laryngoscope. When direct laryngoscopy is difficult, early conversion to an alternative technique reduces the risk of airway compromise and associated morbidity.
Many alternative intubation devices are now available, and part of the anesthesiologist's task is to select the alternative approach best suited to each patient's specific features. Despite its use for both elective and unexpectedly difficult intubation, predictive criteria for successful airway management with the flexible fiberscope have not been developed.
The purpose of this study is to identify patient morphometric or morphological characteristics, if any, that could predict difficult intubation when using the flexible fiberscope for perioperative tracheal intubation in an elective surgical population.
研究设计
- 研究类型
- Interventional
- 分配方式
- Na
- 干预模型
- Single Group
- 主要目的
- Other
- 盲法
- None
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Age 18 and older
- •Patients undergoing elective surgery under general anesthesia, requiring endotracheal intubation
排除标准
- •Induction planned without neuromuscular blocking agents
- •Need for a rapid sequence induction
研究组 & 干预措施
Intubation with a flexible fiberscope
Following induction of general anesthesia and administration of a neuromuscular blocking agent, intubation will be performed using a flexible fiberscope.
干预措施: Flexible fiberscope (Device)
结局指标
主要结局
Morphologic and morphometric predictors of difficult intubation with the flexible fiberscope.
时间窗: Patients will be followed from induction of anesthesia until the end of intubation, an average of 10 minutes
This study will correlate patients' morphometric and morphologic characteristics with the number of attempts and time needed for intubation using a flexible fiberscope.
次要结局
- Time to successful intubation(Patients will be followed from induction of anesthesia until the end of intubation, an average of 10 minutes)
- Number of attempts to successful intubation(Patients will be followed from induction of anesthesia until the end of intubation, an average of 10 minutes)
- Score on the Intubation Difficulty Scale(Patients will be followed from induction of anesthesia until the end of intubation, an average of 10 minutes)