Comparative Effects of Instrument Assisted Soft Tissue Mobilisation and Dynamic Cupping on Elbow Range of Motion and Function in Children With Post Fracture Elbow Stiffness
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 入组人数
- 28
- 试验地点
- 1
- 主要终点
- Disabilities of the Arm, Shoulder, and Hand Questionnaire
研究概览
简要总结
Children who experience fractures may develop stiffness and limited range of motion in their affected joints, notably the elbow. Although conventional rehabilitation approaches have demonstrated some effectiveness, innovative methods like Instrument Assisted Soft Tissue Mobilization (IASTM) and Dynamic Cupping hold promise for enhancing outcomes. These techniques represent emerging therapies aimed at improving range of motion and function across different musculoskeletal conditions. However, there is a lack of comparative research examining their efficacy specifically in pediatric patients with post-fracture elbow stiffness
详细描述
This will be a randomized clinical trial conducted on 28 participants. Data will be collected from Khatoon e Jannat hospital, Mujahid hospital and children hospital of Faisalabad. The study includes children aged 6 to 15, both genders, experiencing elbow postoperative stiffness and with a loss of extension of at least -30 degrees and/or flexion of no more than 120 degrees. Participants excluded from the study are those who declined consent, had pathological fractures, and associated ipsilateral injuries, bilateral upper extremity injuries, neuro-vascular disorders, heterotrophic ossification, or contraindications for IASTM. A sample of 28 will be divided in to two groups. Each group will consist of 14 participants. Group A will receive instrument assisted soft tissue mobilization. On the contrary group B will receive dynamic cupping therapy. Both groups will be given conventional therapy along with prescribed intervention. Intervention will be given for 30 minutes for 3 sessions per week for 4 weeks. Data will be collected before and after the intervention to assess range of motion and function with a help of goniometer and Disability arm shoulder and hand questionnaire. Data will be analyzed by using SPSS version 26.0
研究设计
- 研究类型
- Interventional
- 分配方式
- Randomized
- 干预模型
- Parallel
- 主要目的
- Other
- 盲法
- Single (Participant)
盲法说明
This will be a randomized upping c clinical trial on 28 participant on 6 to 15 years group A will get instrument assisted soft tissue mobilisation and group B will get dynamic
入排标准
- 年龄范围
- 6 Years 至 16 Years(Child)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Age from 6 to 15 years (23)
- •Both genders Participant with elbow postoperative stiffness with loss of extension of ≥-30 degrees and/or flexion ≤120 degrees Participant with at least 6-week post-surgery with open reduction and internal fixation done for either of the following fractures.
排除标准
- •Participants who declined consent.
- •Participants who had pathological fractures, associated ipsilateral injuries, bilateral upper extremity injuries, neuro-vascular disorders, heterotrophic ossification, and contraindications for IASTM
研究组 & 干预措施
Instrumental assisted soft tissue mobilization
Instrument assisted soft tissue mobilization (IASTM) and dynamic cupping are manual therapy techniques used to address soft tissue restrictions and improve joint mobility and function. In the context of children with post-fracture elbow stiffness, these techniques can have several physiological effects. (14) This process involves the use of specialized tools to apply pressure and friction to the affected soft tissues. Which can help break down scar tissue and adhesions that may have formed following the fracture, allowing for improved tissue flexibility and mobility. This can stimulate blood flow to the area, promoting tissue healing and reducing inflammation
干预措施: IASTM (Other)
Dynamic cupping therapy
Dynamic cupping, on the other hand, utilizes suction cups placed on the skin to create negative pressure. This can help stretch and release tight muscles and fascia, increasing tissue flexibility and reducing stiffness. The rhythmic movement of the cups which can also stimulate lymphatic drainage and promote circulation, this will increase the removal of metabolic waste products and will also reduce swelling. (16) Both the techniques can help address the underlying soft tissue restrictions and joint stiffness commonly seen following a fracture. By improving tissue flexibility reducing inflammation, and enhancing circulation IASTM and dynamic cupping can contribute to restoring normal elbow range of motion and function in children with post fracture elbow stiffness. Instrument assisted soft tissue mobilization is one of the recently used popular myofascial intervention. It is known to improve the range of motion, function and improvestrigger point of the muscles. In recent studies it i
干预措施: Dynamic cupping therapy (Other)
结局指标
主要结局
Disabilities of the Arm, Shoulder, and Hand Questionnaire
时间窗: 6 weeks
Function was assessed by the Disability of arm shoulder and hand questionnaire (DASH) (Reliability- ICC- 0.96; validity- 0.70), which is a 30-item patient-reported questionnaire, which can rate difficulty and interference with function on a 5-point Likert scale used to evaluate impairments, activity limitations, as well as participation restrictions in both leisure activities and work due to elbow dysfunction, regardless of which arm is affected. The scores for all items are then summed up to a scale score, where higher scores indicate higher disability
Goniometer Measurement for Range of motion
时间窗: 6 weeks
Universal goniometer is a device which is used to measure the range of motion of the joint. It has both art and science of measuring joint plane by 2 form. It has short and long arm. It has 3 parts Center part is known as fulcrum or axis with two arms. One is moving arm and the other is stationary or fixed arm. ROM of the elbow joint and forearm was measured using the universal half goniometer (Reliability-ICC-0.53-0.97.) Positions used to measure elbow flexion-extension were in supine position, whereas the forearm pronation-supination was done in sitting position .
Numeric Pain rating Scale
时间窗: 6 weeks
Numeric pain rating scale is a subjective measure 11 point numerical scale which is used to measure pain. Is scoring range In this scale 0 shows no pain and 10 shows worst pain imaginable. It has good reliability of 0.79 and validity of 0.96. (26)
次要结局
未报告次要终点