The goal of this feasibility study is to learn if individuals without formal radiology training can safely acquire adequate x-ray images following a structured training and real-time remote guidance from a licensed radiologic technologist (RT). The main question it aims to answer is:
- Can trained non-radiology staff, with real-time remote supervision, obtain x-ray images that meet preset technical quality standards for each required view?
- Can these staff perform x-ray exams safely, as shown by low operator exposure, few image re-takes, and good adherence to radiation safety protocols?
- What is the mental and physical workload for the non-radiology staff and the remote RT during the imaging process, as measured by the NASA Raw Task Load Survey (RTLX) after each session?
研究设计
- 研究类型
- Interventional
- 分配方式
- Na
- 干预模型
- Single Group
- 主要目的
- Treatment
- 盲法
- None
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 是
入选标准
- •Adults aged 18 or older
- •Able to read, speak, and understand English sufficient to follow study instructions and complete evaluation
- •Able to provide verbal consent
- •Currently employed as a medical assistant in a clinical or outpatient setting or actively enrolled in an accredited medical assistant training program
- •Willing to wear a personal dosimeter and comply with all radiation safety procedures
- •Willing to participate in all trainings
排除标准
- •Prior or current professional training, certification, or education in radiography (formal or informal)
- •Prior experience performing x-rays
- •a) including any prior hands-on testing experience with the ENDURO DR ES90 portable x-ray (prior observation or exposure to ENDURO DR is permitted)
- •Pregnancy or possible pregnancy (self-report)
- •Any condition or circumstance that would make participation unsafe
结局指标
主要结局
Proportion of x-ray images rated as "diagnostically accurate"
时间窗: Immediately following each x-ray image acquisition
Remote RT rates diagnostic adequacy of each image using a structured evaluation form
次要结局
- X-ray operator reported workload(Within 24 hours from imaging session)
- Operator radiation exposure(60 minutes from start of each imaging session)
- X-ray operator qualitative interview(Within one week of imaging session)
研究者
David Levine
Clinical Director of Research & Development at Healthcare at Home at Mass General Brigham
Brigham and Women's Hospital
研究点 (1)
Loading locations...
相似试验
尚未招募
不适用
Effectiveness of skill enhancement training on selected parameters of deaddiction care by nurses working at tertiary care hospitalCTRI/2026/03/106665PRIYANKA MALHOTRA160
已完成
不适用
Effects of a Cadaveric Workshop on Self-Reported Confidence in Ultrasound-Guided Upper Extremity ProceduresNCT07615543Istanbul Physical Medicine Rehabilitation Training and Research Hospital78
尚未招募
不适用
A study to find a reliable radiological landmark for accurately locating the central venous catheter position.CTRI/2024/07/071750Dr Kripa Sarah Roy541
招募中
Unknown
中国超声造影培训-多中心回顾性研究ChiCTR2000035750
尚未招募
不适用
Triage Radiology Imaging Assessment for Greater EffectivenessBrainNCT07671664King's College London100,800