Nano-Ceramic Coating for Laparoscope Lens: a Cheap Magical Solution for Lens Fogging and Smearing
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 入组人数
- 55
- 试验地点
- 1
- 主要终点
- rate of fogging or smearing (per hour)
研究概览
简要总结
The investigator tests the effectiveness of nano-ceramic coating when applied (painted) on laparoscope lens to protect it from fogging or smearing during laparoscopic operations
详细描述
A Ceramic Coating is a liquid polymer that is applied by hand to surfaces to make them resistant to scratching, staining, rust or oxidation, as well as "hydrophilic", meaning that water or mud doesn't stick to them and so, they become much easier to clean. It was publicly commercialized in recent years for use on automobiles to preserve their gloss, protect their paint, preserve the clarity of their wind shields and headlights so as to provide better lighting and vision.
On the other hand, lens fogging and other vision-obstructing events during laparoscopic or endoscopic operations(e.g. being smeared by blood or other body fluids during operation, or having a piece of loose tissue stick to its surface that require manual removal and wiping) have been an ever-lasting concern for operators ever since the advent of the respective devices. Many techniques and methods have developed, tested and compared regarding their effectiveness in protecting the lens from such events and preserving vision clear and uninterrupted during operations. Examples of such methods are (scope warmers, FREDTM, ResoclearTM, chlorhexidine, betadine and immersion in heated saline.
In this study the investigator seeks to apply the idea of nano-ceramic coating as a new technique for achieving that goal. to the investigator's best knowledge, this idea was never conceived or tested in the field before.
研究设计
- 研究类型
- Observational
- 观察模型
- Case Only
- 时间视角
- Prospective
入排标准
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Any patient requiring laparoscopic operation
排除标准
- •Any intra-operative event or obstacle that requires conversion to open surgery
结局指标
主要结局
rate of fogging or smearing (per hour)
时间窗: One month
The investigator calculates the number of times the lens is visibly fogged or smeared per hour of operation.
The time consumption for lens cleaning (per single operation)
时间窗: One month
The investigator calculates the time consumption of the cleaning process as a total (in minutes) per single operation.
rate of extraction for cleaning (per hour)
时间窗: One month
The investigator calculates the number of times the lens needs to be extracted from the abdomen for cleaning per hour of operation.
The time consumption for lens cleaning (per hour)
时间窗: One month
The investigator calculates the time consumption of the cleaning process as a total (in minutes) per hour.
rate of fogging or smearing (per single operation)
时间窗: One month
The investigator calculates the number of times the lens is visibly fogged or smeared during a single operation.
Rate of extraction for cleaning (per operation)
时间窗: One month
The investigator calculates the number of times the lens needs to be extracted from the abdomen for cleaning per single operation.
Cleaning difficulty (per hour)
时间窗: One month
The investigator calculates how many times the lens needed more measures for cleaning than simple wiping E.G immersion in hot saline per hour
Cleaning difficulty (per single operation)
时间窗: One month
The investigator calculates how many times the lens needed more measures for cleaning than simple wiping E.G immersion in hot saline per hour