跳至主要内容
临床试验/NCT00167570
NCT00167570已完成不适用

Long Term Clinical Evaluation of SLS Transtibial Sockets

The University of Texas Health Science Center at San Antonio1 个研究点 分布在 1 个国家目标入组 11 人开始时间: 2003年4月最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
11
试验地点
1
主要终点
Durability during household and community mobility.

研究概览

简要总结

The overall long-term goal of this project is the development of a clinically practical system for rapid prosthetic limb provision that integrates computer-aided design with solid freeform fabrication techniques. This proposal builds on our previous successful demonstration of the feasibility of SFF socket fabrication and will address several key issues that underlie its clinical viability. The specific objectives of the proposed work are:

  1. To develop improved designs for SFF transtibial prosthetic sockets that allow the use of industry standard pylon mounts and incorporate variable compliance elements.
  2. Determine the clinical effectiveness of variable wall compliance elements in enhancing the comfort and fit of transtibial prosthetic sockets.
  3. Determine the durability and functionality of SFF sockets during extended clinical use.

These objectives will be met over a three-year period. The initial phase of the proposed work will use an iterative engineering design - modeling - evaluation process to develop variable compliance elements and an industry standard pylon mount adapter. During the second phase of the proposed work, clinical evaluations of SFF prosthetic sockets will be studied. The effectiveness of variable compliant elements in enhancing comfort and fit will be determined using a within subject case comparison study of SFF sockets with conventional laminated sockets. Durability of SFF sockets that incorporate an industry standard pylon mounting system will be determined during a 12-month clinical field trial.

详细描述

Successful rehabilitation for the majority of lower extremity amputees includes prosthetic limb fitting and training. Critical to the success of prosthetic fitting is a comfortable, well fitting socket. Accomplishing this remains a clinical challenge with residual limb pain and socket discomfort affecting 20-55% of lower limb amputees. Achieving an acceptable socket fit using conventional prosthetic techniques requires individual custom molding and fabrication in a labor intensive, costly process. Alternative methods of fabricating prosthetic sockets that can improve efficiency in prosthetic provision, enhance comfort and fit, or reduce cost are needed to ensure the continued optimal rehabilitation of the amputee. This project will continue the development of a new promising method of socket fabrication using solid freeform fabrication (SFF) based on selective laser sintering (SLS) technology. SFF allows the direct manufacture of a prosthetic socket without the intermediate molds and laminating process required with conventional techniques.

The overall long-term goal of this project is the development of a clinically practical system for rapid prosthetic limb provision that integrates computer-aided design with solid freeform fabrication techniques. This proposal builds on our previous successful demonstration of the feasibility of SFF socket fabrication and will address several key issues that underlie its clinical viability. The specific objectives of the proposed work are:

  1. To develop improved designs for SFF transtibial prosthetic sockets that allow the use of industry standard pylon mounts and incorporate variable compliance elements.
  2. Determine the clinical effectiveness of variable wall compliance elements in enhancing the comfort and fit of transtibial prosthetic sockets.
  3. Determine the durability and functionality of SFF sockets during extended clinical use.

These objectives will be met over a three-year period. The initial phase of the proposed work will use an iterative engineering design - modeling - evaluation process to develop variable compliance elements and an industry standard pylon mount adapter. During the second phase of the proposed work, clinical evaluations of SFF prosthetic sockets will be studied. The effectiveness of variable compliant elements in enhancing comfort and fit will be determined using a within subject case comparison study of SFF sockets with conventional laminated sockets. Durability of SFF sockets that incorporate an industry standard pylon mounting system will be determined during a 12-month clinical field trial.

研究设计

研究类型
Observational

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • All subjects will be lower extremity amputees of at least one year duration and are 18 years of age or older.
  • They must meet the Medicare Functional Classification Level K2 or K3 class for prosthetic use (unlimited household or limited community level ambulator).

排除标准

  • There must be no current stump wounds or breakdown or a history of repeated skin breakdown with adequately fitting prostheses.

结局指标

主要结局

Durability during household and community mobility.

时间窗: Up to 12 months

Subjects were followed for up to 12 months in 3 months intervals for examination of the physical condition of socket and for subject gait assessment with socket

次要结局

  • User perceptions of comfort, fit, and function.(Up to 12 months)

研究者

申办方类型
Other
责任方
Sponsor

研究点 (1)

Loading locations...

相似试验