Self Abrading Rapidly Applied (SARA) Electrode Phase II
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 发起方
- 入组人数
- 40
- 试验地点
- 2
- 主要终点
- Signal Quality Comparison Between SARA Electrode and Gold Cup Electrode
研究概览
简要总结
The SARA (Self Abrading Rapidly Applied) electrode will speed EEG patient hookup by combining multiple steps that burden conventional EEG procedures into one. The investigators believe that the proposed system will reduce patient hookup time by more than 50% (from 40 to 20 minutes) with additional time savings on cleanup. Reducing the hookup time required for the EEG recording will make EEG more feasible in time critical situations and will improve patient care and service. The clinical testing in Phase II will investigate patient acceptance, clinician acceptance, time savings, and signal quality for 3 different environments: the large hospital institution, a small rural hospital setting and in an emergency department.
详细描述
The SARA (Self Abrading Rapidly Applied) electrode will speed EEG patient hookup by combining multiple steps that burden conventional EEG procedures into one. This proposed single-use electrode will consist of a Snap Top, Ag/AgCl Snap Conductor, Conductive Adhesive, and Abrader Tines in a custom molded housing and packed on a backing sheet. After removing the backing, the technician simply parts the hair with one hand and with the other hand rubs the electrode back and forth and then presses the electrode into position on the scalp. The proposed system combines the cumbersome and time-consuming skin preparation, electrode preparation and electrode fixation into one easy step. The investigators believe that the proposed system will reduce patient hookup time by more than 50% (from 40 to 20 minutes) with additional time savings on cleanup. Reducing the hookup time required for the EEG recording will make EEG more feasible in time critical situations and will improve patient care and service.
研究设计
- 研究类型
- Interventional
- 分配方式
- Non Randomized
- 干预模型
- Parallel
- 主要目的
- Diagnostic
- 盲法
- Single (Outcomes Assessor)
入排标准
- 年龄范围
- 12 Years 至 —(Child, Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 是
入选标准
- •adult and teenage
排除标准
- •young children
- •damaged scalp skin
- •sensitive or allergic to electrode paste
结局指标
主要结局
Signal Quality Comparison Between SARA Electrode and Gold Cup Electrode
时间窗: up to 1 hour
The time it takes in seconds to properly place the SARA electrodes and standard gold cup electrodes will be recorded and compared.
次要结局
未报告次要终点