Compares Changes in Pulmonary ITV Secondary to Vascular Filling to Reference Values Represented by Changes in Subaortic ITV in the Management of Sepsis in the Emergency Department.
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 入组人数
- 26
- 试验地点
- 1
- 主要终点
- Demonstration of a correlation between changes in pulmonary ITV secondary to vascular filling and reference values represented by changes in subaortic ITV.
研究概览
简要总结
This is a multicenter study conducted in the emergency department of the Nantes University Hospital and the Confluent Private Hospital, over a period of 5 months, based on hemodynamic ultrasound.
For each patient admitted to an emergency department with a sepsis syndrome requiring vascular filling, the pulmonary ITV and the aortic ITV were measured at each phase of vascular filling.
This is a non-interventional study, the management of patients will not differ from usual practices and vascular filling should not be delayed in any case. Emergency doctors who are already experts in ultrasound, monitoring vascular filling by measuring the aortic ITV, will have to measure the pulmonary ITV after each filling of 250cc of Ringer's Lactate in 10 minutes with a limited amount of time.
The evolution of ITV measurements and vital parameters should be recorded for each patient.
In order to ensure quality, the emergency doctors will first receive a short training (presentation of the study and review of the measurements requested). In addition, measurement records will be analyzed at random.
At the end of this study, the correlation between the variation of the aortic and pulmonary ITV could be compared. The objective would be to promote the monitoring of these unstable patients via the pulmonary ITV. This measurement would be easier to perform than the aortic ITV, which is currently only performed by emergency doctors who are experts in hemodynamic ultrasound.
研究设计
- 研究类型
- Observational
- 观察模型
- Cohort
- 时间视角
- Prospective
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- 未提供
排除标准
- 未提供
结局指标
主要结局
Demonstration of a correlation between changes in pulmonary ITV secondary to vascular filling and reference values represented by changes in subaortic ITV.
时间窗: 5 months
Aortic ITV and pulmonary ITV
次要结局
- Investigate whether pulmonary ITV is more feasible than aortic ITV.(5 months)
- Exploratory search for an indicator threshold for pulmonary ITV corresponding to the 10% threshold of aortic ITV (provided that pulmonary ITV and aortic ITV are correlated)(5 months)