跳至主要内容
临床试验/NCT06156644
NCT06156644尚未招募不适用

Pulsed-Field-Ablation to Treat Atrial fiBRillation With a novEl multimodalIty Generator

University Hospital Freiburg0 个研究点目标入组 50 人开始时间: 2025年7月1日最近更新:
适应症

试验速览

阶段
不适用
状态
尚未招募
发起方
入组人数
50
主要终点
number of death

研究概览

简要总结

In this first-in-human clinical trial a novel generator (INTELLAPULSE), designed and built by Stockert, which supports highly flexible PFA protocols as well as RF interventions will be used. For 12 months and follow-up for 12 months, after a 3-months blanking period 50 consecutive paroxysmal AF patients, eligible for catheter ablation, will be enrolled.

详细描述

The principal safety and efficacy of PFA have been established in previous studies, showing low compli¬cation rates, short procedure times, and non-inferior/ superior efficiency compared to thermal abla¬tion.18, 19 However, current generators available for clinical practice are not generally designed to allow both non-thermal and thermal ablation in single shot settings. Moreover, modification of PFA sequences is not supported in commercially available systems. Flexible, multi-modal generators that allow one to conduct PFA or RF ablation using one and the same catheter would be highly desirable, from a clinical point of view, to allow for on-the-fly decision-making in view of individual patient requirements.

In this first-in-human clinical trial a novel generator (INTELLAPULSE), designed and built by Stockert, which supports highly flexible PFA protocols as well as RF interventions will be used. This generator will be CE marked in Q3/24. Upon completion of the ethical approval process in Q2/25, the 'first in human' study, exploring safety of the Stockert PFA generator will be started.

The trial will be a prospective single arm study at the UHZ Freiburg · Bad Krozingen and will recruit for 12 months and follow-up for 12 months, after a 3-months blanking period. 50 consecutive paroxysmal AF patients, eligible for catheter ablation, will be enrolled. Exclusion criteria will be age <18 years, previous left atrial ablation, and lack or withdrawal of written informed consent. Data acquisition will use an electronic case report form (RedCap Database). Procedures will be performed using standard operating procedures (SOP).

In short: ablations will be performed under deep analgo-sedation and/or general anaesthesia. Trans¬oesophageal echocardiography will be performed if patients present with either AF or atrial tachycardia (to exclude intracardiac thrombi) or in sinus rhythm (in patients with interrupted oral anticoagulation and CHA2DS2-VASc-Score ≥2). Atrial transseptal puncture will be performed for access to pulmonary veins (PV), using a fixed curve transseptal sheath and transseptal needle according to standard SOP. PFA catheters (FARAWAVE™, Boston Scientific) will be utilized, as in prior work with a commercial PFA system (FARAPULSE™, Boston Scientific) at the UHZ. At every PV antrum, 8 PFA-pulses will be delivered in 'flower' and 'basket' configurations (delivery of additional PFA-pulses will be at operator's discretion).

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Other
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • new onset atrial fibrillation

排除标准

  • age <18 years
  • previous left atrial ablation
  • lack or withdrawal of written informed consent
  • unable to receive ablation therapy

结局指标

主要结局

number of death

时间窗: 12 month

Primary endpoints focusing of the safety of the strategy

次要结局

未报告次要终点

研究者

发起方
University Hospital Freiburg
申办方类型
Other
责任方
Principal Investigator
主要研究者

PD Dr. Dirk Westermann

Prof

Universitätsklinikum Hamburg-Eppendorf

相似试验