简要总结

This study was conducted to evaluate and compare the effect of acetal resin versus Polyether ether ketone (PEEK) partial dentures on abutment teeth supporting structures in Kennedy class I mandibular partial denture cases. Clinical assessments were conducted by assessing the pocket depth (PD), plaque index (PI), and gingival index (GI). Cone beam computed tomography (CBCT) was used to assess abutment alveolar bone height change.

详细描述

This study was a parallel, two-group, double-blinded, randomized clinical trial. The proposal and consents were approved by the Research Ethics Committee. (REC) approval (P-PD-14-14). The Helsinki Declaration's guiding principles were followed when conducting the study. The Comprehensive Standards of Reporting Trials Statement (CONSORT) checklist's structure is followed in the study's presentation. The study was carried out at the Outpatient Clinic of the Removable Prosthodontic Department within the Faculty of Dental Medicine for Girls at Al-Azhar University.

In this study, fifty patients were initially evaluated. After conducting clinical and radiographic assessments, twenty patients who satisfied the inclusion criteria were selected in accordance with the sample size calculation. Each patient received an explanation of every procedure, and informed consent was obtained. These twenty individuals were subsequently divided randomly into two distinct groups (ten in each):

Group I: Ten patients received polyoxymethylene (acetal resin) partial dentures designed and fabricated using CAD/CAM technology. Group II: Ten patients received polyether ether ketone (PEEK) partial dentures designed and fabricated using CAD/CAM technology.

All patients were evaluated clinically and radiographically. Clinical assessments were conducted by assessing the pocket depth (PD), plaque index (PI), and gingival index (GI) at denture insertion, three months later and six months later. Cone beam computed tomography (CBCT) was used to assess abutment alveolar bone height change at the time of denture placement, after three months, and after six months.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Health Services Research
盲法
Double (Participant, Outcomes Assessor)

盲法说明

(patients and assessors)

入排标准

年龄范围
40 Years 至 50 Years(Adult)
性别
Male
接受健康志愿者

入选标准

  • Every subject should be free of any systemic diseases that might influence the results of the research.
  • Patient's residual ridges should be covered with healthy mucosa.
  • Their salivary flow and viscosity for all within normal limits.
  • The patients are cooperative and ready to be called back as necessary.
  • had a Class I Angle's ridge relation

排除标准

  • Alcoholic or smokers' patients.
  • Patients with xerostomia or excessive salivation.
  • Patients with parafunctional habits.
  • Patients with ulcerated or inflamed mucosa.

研究组 & 干预措施

Acetal resin partial dentures

Active Comparator

ten patients received acetal resin partial dentures designed and fabricated using CAD/CAM technology

干预措施: Acetal resin (Biological)

PEEK partial dentures

Active Comparator

ten patients received polyether ether ketone (PEEK) partial dentures designed and fabricated using CAD/CAM technology.

干预措施: Acetal resin (Biological)

结局指标

主要结局

Pocket Depth

时间窗: 6 months

assessing the pocket depth (PD) of abutment teeth

次要结局

  • Plaque index(6 months)
  • Gingival index(6 months)