The Value of Multimodal Monitoring in the Treatment of Compartment Syndrome: a Study Based on Healthy Volunteers
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 发起方
- 入组人数
- 25
- 试验地点
- 1
- 主要终点
- Blood flow spectrum of the radial artery and dorsal artery by ultrasound Doppler examination
研究概览
简要总结
compartment syndrome has a high incidence in patients with a variety of diseases, including fractures, and delayed diagnosis or without intervention can lead to severe adverse prognosis, such as limb deformities, amputations and even death. Early diagnosis and early intervention are important, especially early diagnosis. Now, the diagnosis of compartment syndrome in clinical is based on medical history, clinical manifestations and measuring the compartment pressure by fine needle puncture. However, this diagnostic method is not easy to achieve early accurate diagnosis and non-invasive continuous monitoring. The study found that the increase of compartment pressure can lead to local changes of hemodynamic, tissue metabolism and nerve function. There are also studies and reports of near-infrared spectral tissue oxygen measurement technology, ultrasonic Doppler technology, near-infrared spectral pulse oxygen measurement technology and infrared thermal imaging technology can be used for noninvasive monitoring of acute compartment syndrome, but it is not clear that which is better above in early diagnosis of acute compartment syndrome.
The purpose of this study was to simulate the process of early pressure increase in the compartment by pressurizing the volunteers' calves by cuff, and then measured the tissue oxygen in the Anterior fascia compartment using a non-invasive monitor of the tissue oxygen parameters, the ultrasonic machine measured the blood flow signal of the upper and lower backbone blood vessels, and the blood oxygen meter to measure the blood saturation of the upper and lower ends of the limb. The infrared thermal imager measured the near and far limb temperature of the hemostatic belt and the two-point identification of the skin sensory nerve function at the far end of the fascia chamber. Then compare the correlation of these indicators with pressure changes.
详细描述
The participants is health volunteers, age 18-60 years. When the participants agree to participate in the experiment, the experimenter first needs to explain the experimental process to the participants, and ask the participants to agree and sign the informed consent before they can conduct the experiment. The experiment was conducted in the emergency medicine department of a university-affiliated top three hospital.
When the participants are included in the experimental study, the general demographic information of the participants, such as name, gender, age, etc., is first collected. Ensure the experimental environment is comfortable, ambient temperature 20-24℃, ambient humidity 50-60%. Participants have loose clothing on their lower limbs to avoid pressure on their limbs. Take the supine position, keep the calf hanging, support the heel, make the calf level flush with the heart, rest for 5 minutes.
The monitor (M3002A, Philips Medizin Systeme Boeblingen GmbH, Germany) was used to continuously monitor the electrocardiogram, the left upper arm measured blood pressure (BP), and the right middle finger to monitor pulse oximetry (SpO2). The calf circumference was measured at the midpoint of the bilateral humerus with a soft ruler. The maximum thickness of anterior fascia compartment was measured at the midpoint of the tibia using an ultrasonic machine (Acclarix AX8, Shenzhen Libang Precision Instrument Co., Ltd., China).
The random number table method selects one side of the calf as the experimental side and the opposite side as the control side.
(8) The following parameters were recorded at baseline (pressure 0mmHg in the calf tourniquet on both sides): (1) heart rate, blood pressure; (2) right middle finger, lower limbs, middle toe finger vein oxygen SpO2; (3) bilateral Local blood tissue parameters (TOI, THI, ΔCHb, CHbO2, ΔCtHb) in the calf; (4) Near-infrared thermography temperature values (T-u1, T-u2) in the knee and thighs of the lower leg and the instep and toe Near-infrared thermography temperature values (T-d1, T-d2); (5) bilateral radial artery ultrasound Doppler measurement parameters (D-pa, S-pa, Vs-pa, Vd-pa, DRAF-pa) Ultrasound Doppler measurement parameters of bilateral iliac veins (D-pv, S-pv, Vs-pv, Vd-pv), bilateral posterior tibial artery and dorsal artery ultrasound Doppler measurement parameters (Vs-pta, Vd -pta, SFAF-pta, Vs-da, Vd-da, SFAF-da). (6) Two-point identification threshold TPD.
研究设计
- 研究类型
- Interventional
- 分配方式
- Randomized
- 干预模型
- Parallel
- 主要目的
- Diagnostic
- 盲法
- None
入排标准
- 年龄范围
- 18 Years 至 60 Years(Adult)
- 性别
- All
- 接受健康志愿者
- 是
入选标准
- •Healthy adults, aged 18-60 years; No obvious cardiovascular diseases such as cardiovascular and cerebrovascular diseases; Complete limbs without deformity and no history of lower limb trauma; Informed consent
排除标准
- •pregnancy or use of oral contraceptives; History of diabetes; History of deep vein thrombosis; Peripheral neuropathy; peripheral vascular disease; History of rhabdomyolysis
研究组 & 干预措施
compartment syndrome model group(CSM group)
干预措施: acute compartment syndrome model of health volunteer (Procedure)
sham group
干预措施: sham (Procedure)
结局指标
主要结局
Blood flow spectrum of the radial artery and dorsal artery by ultrasound Doppler examination
时间窗: 40 minutes
During the cuff compression, the blood flow spectrum of the radial artery and dorsal artery was recorded by the ultrasound, and analyzed later for the blood direction and duration.
tissue oxygen of the compartment by Infrared oxygen saturation monitor
时间窗: 40 minutes
The infrared oxygen saturation monitor probe is placed on the anterior surface of the anterior fascia, and the changes of tissue oxygen index are continuously monitored during the process of cuff compression.
次要结局
- Systemic hemodynamics(40 minutes)
- Pulse oxygen(40 minutes)
- Two-point identification check(40 minutes)
- temperture changes by near-infrared thermography(40min)