跳至主要内容
临床试验/NCT06028919
NCT06028919已完成不适用

A Randomised Control Trial of Power Versus Temperature-controlled Irrigated Radiofrequency Ablation for the Treatment of Ventricular Tachycardia (VT)

University Hospitals Coventry and Warwickshire NHS Trust3 个研究点 分布在 1 个国家目标入组 61 人开始时间: 2022年9月26日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
已完成
入组人数
61
试验地点
3
主要终点
Assessing the efficacy of the DT versus the TF ablation catheter for the treatment of VT

研究概览

简要总结

Ventricular Tachycardia (VT) is a life threatening heart rhythm that comes from the bottom chambers of the heart (the ventricles) and is a leading cause of sudden cardiac death.

The majority of patients that are at risk of VT or suffer a cardiac arrest will have an Internal Cardiac Defibrillator (ICD) in situ to treat the abnormal heart rhythm. The ICD can deliver a painful shock to restore normal heart rhythm but importantly does not treat the underlying cause. Current treatment for the prevention of recurrent VT include catheter ablation (CA) or medication. Long-term results with global 12 month VT-free survival rates with CA are around 50%.

The trial is to compare 2 different types of ablation catheter that are used to cauterise small areas of unhealthy tissue within the heart that are responsible for VT: Diamond Temp (DT) and Tacticath/Tactiflex (TF). Our hypothesis is that the DT ablation catheter will provide comparable efficacy and safety for the treatment of VT as the current industry gold standard (TF).

详细描述

This trial compares 2 different types of ablation catheter for the treatment of ventricular tachycardia (VT). VT is a life threatening heart rhythm that comes from the bottom chambers of the heart (the ventricles) and is associated with poor patient prognosis, outcomes and is a leading cause of sudden cardiac death in developed countries.

Current treatments for VT include catheter ablation (CA), medication and having an internal cardiac defibrillator (ICD) implanted, each treatment has advantages and disadvantages. The ICD can deliver a lifesaving shock but this doesn't treat the cause of the VT and can be very painful and upsetting for the patient. Medications can reduce the amount and rate of VT but can have dangerous side effects.

CA involves small tubes being placed in the heart and small areas of unhealthy heart tissue are burnt (ablated) to stop the VT. This is the only treatment that treats the underlying cause but long-term success is about 50% after 1 year.

The investigators want to improve the success rates of VT ablation. There is a new ablation catheter called Diamond Temp which works differently to the current industry gold standard (Tacticath/Tactiflex Catheter). The investigators think the Diamond Temp catheter will be better than the Tacticath catheter but need to do this trial to prove it.

This trial will be at University Hospital Coventry and Warwickshire and University Hospitals Sussex involving patients that suffer VT, have an ICD and need an ablation. If a patient wishes to participate they will give consent and be chosen at random to receive ablation with either Diamond temp or Tacticath/Tactiflex. All other treatment will be the same as after a normal ablation procedure. Participants will be followed up at 6 months and 1 year after the procedure as well as being monitored by the ICD clinic. The study will have 54 patients and be completed in 2025.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Treatment
盲法
Single (Participant)

盲法说明

The patient will be blinded to which trial arm they have been assigned.

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • ≥ 18 years of age to give informed consent specific to national legal requirements.
  • Subject with 1 of the following:
  • Symptomatic VT (despite optimal medical therapy), 3 or more episodes of VT within 24 h (VT storm).
  • At least 3 episodes of VT requiring anti-tachycardia pacing (ATP)
  • At least one appropriate ICD shock.
  • Referred for VT ablation by Consultant Electrophysiologist
  • Subject discussed at cardiac EP MDT
  • Suitable candidate for intra-cardiac mapping and ablation of arrhythmia.
  • Subject agrees to comply with study procedures and be available for routine follow up visits for at least 12 months after enrolment.
  • Subject is willing and able to provide written consent

排除标准

  • BMI >40kg/m2
  • Presence of intramural thrombus, tumour or abnormality that precludes vascular access, catheter introduction or manipulations.
  • Coagulopathy, bleeding diathesis or suspected pro-coagulant state.
  • Sepsis, active systemic infection or fever (>100.5 F/38 C) within a week prior to the ablation procedure.
  • Significant restrictive or obstructive pulmonary disease or chronic respiratory condition.
  • Renal failure requiring dialysis or renal compromise that in the investigators judgement would increase risk to the subject or deem the subject inappropriate to participate in the study.
  • Known allergies or intolerance to anticoagulant and antiplatelet therapies to be used in conjunction with the study or contrast sensitivity that can't be adequately pre-treated prior to the ablation procedure.
  • Positive pregnancy test results for female subjects of childbearing or potential or breast feeding.
  • Enrolment in a concurrent clinical study that in the judgement of the investigator would increase risk to the subject or deem the subject inappropriate to participate in the study.
  • Significant GI bleed.

研究组 & 干预措施

Temperature controlled DiamondTemp (DT) ablation catheter

Other

Intervention arm

干预措施: Temperature controlled DiamondTemp (DT) ablation catheter (Device)

Power controlled Tacticath/Tactiflex ablation catheter

Other

Control arm

干预措施: Tacticath/Tactiflex (TF) ablation catheter (Device)

结局指标

主要结局

Assessing the efficacy of the DT versus the TF ablation catheter for the treatment of VT

时间窗: 12 months post ablation

The efficacy of each ablation catheter will be compared by measuring the VT burden 12 months post-ablation.

Assessing the safety of the DT versus the TF ablation catheter for the treatment of VT

时间窗: within 30 days or 6 months after index ablation procedure

The efficacy of each ablation catheter will be compared by measuring the freedom from a composite of pre-specified procedure-related complications (adverse outcomes).

次要结局

  • Perceived health benefit of treatment(at baseline and 12 months)

研究者

申办方类型
Other
责任方
Sponsor

研究点 (3)

Loading locations...

相似试验