Assessing the Accuracy of the Butterfly Sensor With RevK Version for Non-Invasive Hemoglobin Monitoring
适应症
试验速览
- 阶段
- 不适用
- 状态
- 终止
- 入组人数
- 9
- 试验地点
- 1
- 主要终点
- The primary purpose of this study is to assess the accuracy of the newly released Masimo SpHb Butterfly Sensor with RevK version and compare the results to a blood hemoglobin level.
研究概览
简要总结
The primary purpose of this study is to assess the accuracy of the newly released Masimo SpHb Butterfly Sensor with RevK version and compare the results to a blood hemoglobin level analyzed in the UCSF Clinical Laboratories. A secondary purpose is to assess the blood hemoglobin using the Masimo Pronto-7 hand-held device immediately prior to surgery.
详细描述
- Masimo SpHb™ continuous hemoglobin monitoring The Masimo SpHb™ monitor with the Butterfly Sensor with RevK version will be used to continuously monitor hemoglobin electronically. The Butterfly Sensor will be connected to the 3rd or 4th finger on either the right or left hand.
- Masimo Pronto-7™ intermittent hemoglobin monitoring The Masimo Pronto-7™ is a hand-held, noninvasive device used for intermittent measuring of blood hemoglobin. The device is connected to a re-usable sensor which is clipped onto a finger for quick spot-check readings. A reading from the Pronto-7 will be taken immediately before surgery.
- Blood sampling for hemoglobin determination For the study, about a ½ tsp of blood will be collected from the arterial line placed for the purpose of surgery approximately every hour during the surgery to obtain a hemoglobin measurement to be analyzed in the UCSF Clinical Lab.
研究设计
- 研究类型
- Observational
- 观察模型
- Cohort
- 时间视角
- Prospective
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Male of non-pregnant female 18 y/o or older
- •American Society of Anesthesiologists Classification 1,2 or 3
- •Scheduled to undergo spine or hip surgery
排除标准
- •Pregnant or nursing
- •Patients who in the investigators clinical judgement would not be suitable for research
结局指标
主要结局
The primary purpose of this study is to assess the accuracy of the newly released Masimo SpHb Butterfly Sensor with RevK version and compare the results to a blood hemoglobin level.
时间窗: During surgery
次要结局
未报告次要终点
研究者
研究点 (1)
Loading locations...
相似试验
已完成
不适用
Development of electrophysiological determination of uterine receptivity (EDUR) system: a performance evaluation test in multiparous women volunteersinfertilityimplantation failureD007247JPRN-jRCTs052190056Kimura Tadashi10
已完成
不适用
Accuracy Characterization StudyType2 DiabetesType1diabetesInsulin Dependent DiabetesNCT01932944Abbott Diabetes Care30
终止
不适用
Evaluation of the Accuracy and Precision of the Masimo Labs Pulse-Hemoglobin-Meter Monitor in Surgical PatientsAdult Patient Undergoing Major SurgeryNCT00762398University of California, Irvine40
已完成
不适用
Evaluation of the Accuracy of the Abbott Sensor Based Interstitial Glucose Monitoring SystemType 2 DiabetesType 1 DiabetesNCT02073058Abbott Diabetes Care75
Unknown
不适用
A Trial to Evaluate the Precision and Accuracy of the NBM-200 Series When Used in a Continuous Prospective ModeAnemiaNCT01917487OrSense, Ltd.150