The Relationship Between Blood Flow Conditions and Sounds in Arteriovenous Fistulae for Hemodialysis
试验速览
- 阶段
- 不适用
- 状态
- 招募中
- 发起方
- 入组人数
- 15
- 试验地点
- 2
- 主要终点
- Correlation coefficient between LHPR and the vein's surface area with OSI > 0.1
研究概览
简要总结
This is a prospective non-pharmacological interventional study aimed at investigating the relationship between the blood flow condition and the arteriovenous fistula (AVF) sound, with the ultimate aim of predicting the AVF clinical, in patients with end-stage renal disease (ESRD) who require the creation of a vascular access for extracorporeal circulation.
详细描述
The native arteriovenous fistula (AVF) is the lifeline for patients on hemodialysis treatment, but it is still affected by high non-maturation and early failure rates, requiring in most of the cases, the creation of a new vascular access.
Despite the exact mechanism underlying stenosis development and consequent AVF failure remains tentative, there is a general consensus that hemodynamic conditions play a key role. The hemodynamic conditions can be studied using computational fluid dynamic simulations (CFD), advanced computational techniques that allow to simulate blood flowing in virtual 3D models generated from medical images. The current gold standard in the clinical studies with CFD is to obtain reliable 3D AVF models from non-contrast enhanced MRI and our group developed a novel MRI protocol for this purpose. However, recent studies performed by other groups suggest that US technique can also provide accurate and reliable models and the hit on the market, and the tUS Piur Device, which was recently made available to the investigators' research group, offers new avenues for non-invasive and inexpensive 3D patient-specific AVF model generation. Previous computational fluid dynamics investigations inside patient-specific AVF models conducted by the investigators revealed transitional turbulent-like flow in the vein. In particular, the investigators evaluated the venous surface areas occupied by high values of the Oscillatory Shear Index (OSI), a well-accepted hemodynamic metric for the identification of disturbed flow conditions, and they found that wide areas of the venous segment of AVFs are characterized by OSI > 0.1. More recently, by using fluid structure interaction simulations, the investigators have shown that such turbulent-like blood flow conditions cause the venous wall to vibrate at high frequencies and that wall vibrations phenotypically collocate with typical regions of stenosis formation. The investigators' hypothesis is that flow-induced vibrations are transmitted to the skin surface of the patient and then result in those palpable thrills and audible bruits that, over the years, nurses and nephrologists got used to qualitatively evaluate using their stethoscopes. However, up to now sound evaluation has only been qualitative and therefore very subjective, but it may provide a strong indication of aberrant hemodynamic conditions and could have a potential as a non-invasive and unexpensive surveillance method.
Therefore, studies aimed at clarifying the relationship between the blood flow conditions and the AVF sound will help advancing the knowledge in the field, providing indications on the role of hemodynamics in AVF failure and bringing out novel methods such as sound analysis for AVF surveillance.
研究设计
- 研究类型
- Interventional
- 分配方式
- Na
- 干预模型
- Single Group
- 主要目的
- Diagnostic
- 盲法
- None
入排标准
- 年龄范围
- 18 Years 至 90 Years(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Provision of informed consent prior to any study specific procedures.
- •Female and/or male aged between 18 and 90 years.
- •Patients in HD treatment who need a new VA or patients who entered the pre-dialysis program because of ESRD. In all cases, the first-choice treatment is the surgical creation of an autogenous AVF in patient's forearm.
排除标准
- •Contraindications for the creation of an autogenous AVF.
- •Presence of a previously failed AVF in the same arm selected for surgery.
- •Patients with contraindications to MRI including: pregnancy, claustrophobia, cardiac pacemakers or other MRI-incompatible prostheses.
- •Patients already on HD treatment through a catheter or a graft.
- •Patients undergoing peritoneal dialysis.
- •Patients with a life expectancy of less than 2 years.
结局指标
主要结局
Correlation coefficient between LHPR and the vein's surface area with OSI > 0.1
时间窗: At each established study visit (i.e., at day 14, at months 3, 6, 12, 24)
LHPR: ratio between the amplitude of maximum peak in the range of low-frequency (100-250 Hz) and the amplitude of the maximum peak at high frequency (500-750 Hz). OSI: oscillatory shear index, common metric for disturbed blood flow.
次要结局
未报告次要终点
