A Randomized Trial Comparing the Diagnostic Sensitivity and Safety of Mini-thoracoscopy Versus Conventional Rigid Thoracoscopy in Undiagnosed Pleural Effusions
试验速览
- 阶段
- 不适用
- 状态
- 招募中
- 发起方
- 入组人数
- 100
- 试验地点
- 2
- 主要终点
- Diagnostic sensitivity (intention-to-treat)
研究概览
简要总结
Consecutive patients who are planned to undergo a medical thoracoscopy for obtaining pleural biopsies will be enrolled in the study.
One hundred subjects will be randomized in 1:1 ratio to undergo thoracoscopy to the following groups:
Group A (mini-thoracoscopy) Group B (Conventional rigid thoracoscopy) Primary outcome: (a) diagnostic sensitivity of mini-thoracoscopy and conventional rigid thoracoscopy in the diagnosis of exudative pleural effusions
详细描述
A significant proportion of patients with pleural effusions remain undiagnosed after performance of diagnostic procedures including cytological and microbiologic analysis of the pleural fluid and closed pleural biopsies. In this study, the investigators plan to compare the yield and safety of mini-thoracoscopy and conventional rigid thoracoscopy with the larger diameter scope.
This is a prospective study that will be conducted at the Thoracic Endoscopy Suite of the Department of Pulmonary Medicine, PGIMER, Chandigarh.
Consecutive patients who are planned to undergo a medical thoracoscopy for obtaining pleural biopsies will be enrolled in the study
One hundred subjects will be randomized in 1:1 ratio to undergo thoracoscopy. The randomization sequence will be generated using a computer (in blocks of 10), and the allocation will be placed in opaque sealed envelopes. The patients will be randomized to the following groups:
Group A (mini-thoracoscopy): The mini-thoracoscope manufactured by Richard Wolf GmbH, Knettligen, Germany will be used. It has an outer diameter of 5.5 mm and a working channel diameter of 3.5 mm.
研究设计
- 研究类型
- Interventional
- 分配方式
- Randomized
- 干预模型
- Parallel
- 主要目的
- Diagnostic
- 盲法
- None
入排标准
- 年龄范围
- 15 Years 至 80 Years(Child, Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Medical thoracoscopy being performed for obtaining a pleural biopsy
排除标准
- •PaO2/FIO2< 300; Hemodynamic instability Myocardial infarction or unstable angina in the last 6 wk Lack of pleural space due to adhesions Uncorrected coagulopathy Failure to provide informed consent
结局指标
主要结局
Diagnostic sensitivity (intention-to-treat)
时间窗: 6 months
Difference between the diagnostic sensitivity of mini-thoracoscopy and conventional rigid thoracoscopy in the diagnosis of exudative pleural effusions by calculating the number of true positives diagnosed by thoracoscopic biopsy in the two groups out of the total diseased
Diagnostic sensitivity (per protocol)
时间窗: 6 months
Diagnostic sensitivity of mini-thoracoscopy and conventional rigid thoracoscopy in the diagnosis of exudative pleural effusions by calculating the number of true positives diagnosed by thoracocopic biopsy. In this analysis, the subjects crossed over to the rigid group (due to failure of minirigid to yield biopsy tissue) will be considered in the rigid group
次要结局
- Sedative and analgesic dose(1 day)
- Pain scores by visual analog scale(1 day)
- Diagnostic specificity(6 months)
- Adverse effects(1 month)
- Scope maneuverability(1 day)
- Ease of obtaining biopsy(1 day)
- Incision size(1 day)
- Procedure duration(1 day)
- Pain scores by Wong Baker FACES pain rating scale(1 day)
研究者
Sahajal Dhooria
Assistant Professor
Post Graduate Institute of Medical Education and Research, Chandigarh
