Functional, Clinical, and Predictive Validation Study of the EMILY AI Device in Patients With Acute and Chronic Respiratory Failure
试验速览
- 阶段
- 不适用
- 状态
- 招募中
- 发起方
- 入组人数
- 20
- 试验地点
- 1
- 主要终点
- EFFICACY - EVALUATION OF THE RATE THE DEVICE MAINTAINS BLOOD OXYGEN SATURATION LEVELS
研究概览
简要总结
Currently, there is no holistic solution for patients with respiratory diseases that includes oxygenation and management of a patient with respiratory disease, combining dynamic and automatic O2 administration and the detection of clinical worsening, generating a diagnostic suspicion, a management proposal, and notifying the medical team.
For device validation, prospective studies will be conducted in patients in respiratory intermediate care units, conventional hospitalization, during physical activity in the hospital setting, and in an out-of-hospital setting. The device will be evaluated in terms of oxygenation efficacy, response time, patient safety, efficiency, versatility, clinical benefit, and adaptability.
详细描述
There is no doubt about the efficacy of oxygen therapy in the treatment of acute and chronic respiratory failure in different clinical settings. However, its therapeutic dosage is not as strict as that of other treatments. Hypoxemia has been associated with increased mortality in multiple pathologies and clinical situations. Furthermore, the liberal use of oxygen therapy has also demonstrated harmful effects. Therefore, titration of this therapy is necessary. Traditionally, this has been performed manually, although in recent years, new devices have been developed to automatically adjust O2 flow rates to the needs of each patient, with the goal of maintaining stable oxygen saturations. These systems have the potential to reduce medical error, improve morbidity and mortality, and reduce care costs.
This study is a clinical investigation using a non-CE marked medical device, prospectively validating the device's functional status. The objective is to evaluate its efficacy and safety in patients with respiratory failure, both in hospital and outpatient settings.
研究设计
- 研究类型
- Interventional
- 分配方式
- Na
- 干预模型
- Single Group
- 主要目的
- Treatment
- 盲法
- None
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Men and women over 18 years of age.
- •Admitted to intermediate respiratory care unit with a diagnosis of acute respiratory failure for at least 8 hours.
- •Informed consent understood and signed.
排除标准
- •Hemodynamic instability.
- •Severe temperature changes.
- •Hemoglobinopathies, severe anemia, severe acidosis, or severe alkalosis.
- •Anatomical disturbances.
- •Pregnancy or breastfeeding.
结局指标
主要结局
EFFICACY - EVALUATION OF THE RATE THE DEVICE MAINTAINS BLOOD OXYGEN SATURATION LEVELS
时间窗: From enrollment to the end of treatment at 8 hours.
Evaluation of the rate that the device maintains blood oxygen saturation levels measured by pulse oximetry within predetermined ranges in patients diagnosed with ARF (hypoxemic patients: 94-98%; hypercapnic patients: 92-94%) without providing less or more oxygen than required to keep the patient within the defined range.
次要结局
- ACCURACY - MEASUREMENT OF THE SYSTEM'S ACTION SPEED CORRECTING THE OXYGEN SATURATION LEVELS(From enrollment to the end of treatment at 8 hours.)
- ALERT SYSTEM - MEASUREMENT OF THE NUMBER OF SYSTEM ALERTS(From enrollment to the end of treatment at 8 hours.)
- ALERT SYSTEM - EVALUATION OF THE AUTHENTICITY OF THE SYSTEM ALERTS BY COMPARING THE OXYGEN SATURATION LEVELS WITH A CONVENTIONAL SYSTEM(From enrollment to the end of treatment at 8 hours.)
- EFFICIENCY - MEASUREMENT OF THE NUMBER OF TIMES THE MEDICAL AND NURSING TEAM MUST ADJUST THE OXYGENATION(From enrollment to the end of treatment at 8 hours.)
- VERSATILITY - COMPARISON OF BLOOD OXYGEN SATURATION LEVELS MAINTENANCE BETWEEN DIFFERENT PROFILES AND SITUATIONS(From enrollment to the end of treatment at 8 hours.)