跳至主要内容
临床试验/NCT03236298
NCT03236298已完成不适用

Programmed Intermittent Epidural Bolus for Labor Analgesia During First Stage of Labor: a RCT Comparing 125 mL/h Versus 250 mL/h Bolus Delivery Flow

Samuel Lunenfeld Research Institute, Mount Sinai Hospital2 个研究点 分布在 1 个国家目标入组 90 人开始时间: 2017年8月1日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
90
试验地点
2
主要终点
Sensory block level to ice equal to or higher than T6 within the study period (6 hours)

研究概览

简要总结

At Mount Sinai Hospital, epidural analgesia for labor pain is delivered by programmed intermittent epidural bolus (PIEB), in combination with pushes of medication activated by the patient, a technique called patient controlled epidural analgesia (PCEA). Studies have shown that delivering analgesia in this manner can prolong the duration of analgesia, diminish motor block, lower the incidence of breakthrough pain, improve maternal satisfaction and decrease local anesthetic consumption comparing to a conventional continuous infusion. The use of this PIEB technique in routine practice has reduced the total consumption of local anesthetic and the percentage of patients requesting additional boluses (PCEA or manual rescues).

However, at the same time, sensory blocks above those targeted for labor pain relief have been reported in our institution, suggesting that the spread of the freezing medication is wider than necessary. Based on the information already available in the literature, the investigators will conduct this study to determine the best regimen of PIEB achievable with a slower delivery speed.

The hypothesis of this study is that PIEB boluses with 125 mL/h will decrease by 50% the incidence of women presenting sensory block to ice equal or higher than T6 as compared to a delivery rate of 250 mL/h.

详细描述

PIEB is a novel technique, which provides better analgesia and less motor block; however, the ideal regimen has not been established. To optimize the PIEB regimen, the investigators have conducted several clinical trials using bupivacaine with fentanyl. Although PIEB provides the excellent analgesia to laboring parturients, studies completed by the instigators have shown that the incidence of sensory block to ice ≥T6 was 66%. For labor analgesia during the first stage of labor, effective sensory block requires T10 to L1; therefore, a sensory block ≥T6 seems unnecessarily high, and the investigators seek to confine epidural spread within a proper range.

Our previous studies showed that the effective volume 90% using 0.0625% bupivacaine was 10.7 mL, and incidence of epidural blockade ≥T6 was similar even using a 5-mL bolus with 0.125% bupivacaine. The investigators concluded that it is not possible to reduce volume of the PIEB, or use a higher concentration of local anesthetic without compromising the quality of analgesia. There is some evidence in the literature that supports the idea that higher injection pressures result in a wider spread of local anesthetic administered into the epidural space, therefore a slower epidural delivery flow rate may result in less spread.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Treatment
盲法
Quadruple (Participant, Care Provider, Investigator, Outcomes Assessor)

入排标准

年龄范围
18 Years 至 55 Years(Adult)
性别
Female
接受健康志愿者

入选标准

  • ASA II or III
  • Term pregnancy (gestational age ≥ 37 weeks)
  • Nulliparous
  • Singleton pregnancy with vertex presentation
  • Active labour defined as occurring regular uterine contractions at least every 5 minutes with progressive cervical dilatation
  • Verbal Numerical Rating Score (VNRS) greater than 5 at requiring epidural analgesia (VNRS 0-10)
  • Cervical dilation between 2 and 5 cm

排除标准

  • Any contraindication to epidural analgesia
  • Accidental dural puncture
  • Drug allergy to lidocaine, bupivacaine or fentanyl
  • Use of pharmacological analgesics within the last 4 hours
  • Patient refusal to participate in the trial

结局指标

主要结局

Sensory block level to ice equal to or higher than T6 within the study period (6 hours)

时间窗: 6 hours

Sensory block to ice will be assessed bilaterally at the mid-clavicular line, and the level of block will be the level at which the patient still does not feel normal cold sensation as compared to a control site (lateral upper arm, frontal part of head or cheek). T6 is defined as the level of the xyphoid process.

次要结局

  • Sensory block level to ice(6 hours)
  • Sensory block level to pin prick(6 hours)
  • Motor block level assessed using Bromage score(6 hours)
  • Pain score(6 hours)
  • Total number of PCEA demands(6 hours)
  • Total number of rescue boluses administered(6 hours)
  • Total amount of local anesthetic (ml)(6 hours)
  • Maternal satisfaction rating(6 hours)
  • Hypotension(6 hours)

研究者

发起方
Samuel Lunenfeld Research Institute, Mount Sinai Hospital
申办方类型
Other
责任方
Sponsor

研究点 (2)

Loading locations...

相似试验