跳至主要内容
临床试验/NCT06212258
NCT06212258进行中(未招募)不适用

Pneumoperitoneum Increases Mean Expiratory Flow Rate: an Observational Study in Healthy-lung Patients

Balázs Sütő1 个研究点 分布在 1 个国家目标入组 67 人开始时间: 2023年10月1日最近更新:
适应症

试验速览

阶段
不适用
状态
进行中(未招募)
入组人数
67
试验地点
1
主要终点
Pneumoperitoneum increases mean expiratory flow rate

研究概览

简要总结

Upon introducing pneumoperitoneum our research team noticed a reduction in expiration time displayed on the screen of the anesthesia machine. Since most respirators do not directly indicate the length of expiratory time and the average expiratory flow rate, we decided to investigate whether pneumoperitoneum really accelerates expiratory flow rate and thus shortens expiratory time.

详细描述

Furthermore we also intended to investigate which ventilation parameters these changes can be correlated with, elucidating the factors contributing to the acceleration of expiration..

This study aims to uncover the physiological mechanisms behind alterations in respiratory dynamics during and after pneumoperitoneum, offering valuable insights that may aid in refining ventilation strategies in the context of laparoscopic procedures.

研究设计

研究类型
Observational
观察模型
Case Control
时间视角
Prospective

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • elective laparoscopic abdominal surgery, healthy lung patients, age over 18 years. Obrained, written informed consent to partake in the research.

排除标准

  • chronic obstructive pulmonary disease, bronchial asthma, silicosis, and those with a history of previous lung surgery, patients under 18 years of age, those who had not provided consent, and pregnant individuals were excluded from the study.

结局指标

主要结局

Pneumoperitoneum increases mean expiratory flow rate

时间窗: during surgery

Elevated intraabdominal pressure leads to a decrease in respiratory compliance and an increase in peak inspiratory pressure., therefore (consequently), expiration commences with a higher pressure difference.

Expiration time would be shortened, resulting in a potentially higher flow rate

时间窗: during surgery

We assumed (hypothesized) that the expiration time would be shortened, resulting in a potentially higher flow rate compared to pre-pneumoperitoneum conditions. Additionally, we also conducted calculations to establish correlations between respiratory parameters and the mean increment in expiratory flow rate relative to the baseline.

次要结局

未报告次要终点

研究者

申办方类型
Other
责任方
Sponsor Investigator
主要研究者

Balázs Sütő

Consultant Anaesthetist

University of Pecs

研究点 (1)

Loading locations...