跳至主要内容
临床试验/NCT01539798
NCT01539798已完成不适用

Changes in Body Composition, Hematological Parameters, and Serum Biochemistry and After Rapid Intravenous Infusion or Oral Intake of 2L of 0.9% Saline Solution in Young Healthy Volunteers. A Randomized Cross-over Study

Federal University of Mato Grosso2 个研究点 分布在 1 个国家目标入组 10 人开始时间: 2011年8月1日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
10
试验地点
2
主要终点
Body Composition

研究概览

简要总结

The investigators conducted a cross-over study to compare the response of healthy young volunteers to a rapid oral intake or intravenous infusion of 0.9% saline solution on the body composition, serum electrolytes, albumin, and hematological parameters.

The investigators hypothesized that these parameters will differently adapt depending on the route of infusion

详细描述

This was a cross over study including ten healthy young males (18-26 years old) with no acute or chronic illness for the last 3 months previously. They were not using any either medications or illicit drugs. Based on their body mass index (BMI) they were neither considered obese nor malnourished (BMI ranged from 22 to 27 kg/m2). They underwent the study after giving written informed consent. The study was approved by the Committee of Ethics in Research of the Julio Muller Hospital (862/CEP-HUJM/2010; Federal University of Mato Grosso, Cuiaba, Brazil). In two separate moments, all participants received in random order 2L of 0.9% saline by either the forearm vein or oral intake as follows.

Procedures The ten volunteers were fasted from midnight and they reported to the laboratory by 8-9 AM for the procedures. After having voided the bladder they were weighted to the nearest 0.1 kg and their heights were measured to the nearest 0.01 m with a estadiometer. Body mass was then calculated. Bioelectrical impedance analysis was performed with single-frequency (50 kHz) device (Bodystat 1500; Bodystat Ltd., Isle of Man, U.K.) using tetrapolar distal limb electrodes. TBW, fatty mass and lean body mass were calculated using regression equations programmed into the devices.

Firstly, a 12 gauge cannula was inserted the forearm and blood samples were collected for laboratory assays: hematocrit, hemoglobin, blood glucose, serum electrolytes (sodium, potassium, chloride and bicarbonate), albumin, creatinine, and osmolality. The volume of the urine output until 2h after the experiment was collected and measured.

Two liters of 0.9% saline were then infused over 1 hour into one of the forearm veins in all participants in supine position. An experienced anesthetist conducted the entire procedure at the laboratory. Blood pressure and pulse rate were taken every 30 minutes for 2h and the volunteers were not allowed to eat or drink during this period. After the infusion of the saline solution they were sent to void the bladder, were weighted again, and another blood sample was taken for the same assays. Another bioelectrical impedance analysis was carried out by the same manner. Two hours after the finish of the infusion they were asked to void the bladder again and the urinary output was registered.

The same volume of saline associated with a non-caloric flavor powder (Tang, Sao Paulo, Brazil) was orally ingested by the same volunteers 4 weeks after the first experiment, in the same room and following the same preparation as described. The blood samples were sent to the laboratory with a code that was broken in the end of the experiment and the data was put in a datasheet for statistical analysis.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Crossover
盲法
Single (Outcomes Assessor)

入排标准

年龄范围
18 Years 至 26 Years(Adult)
性别
Male
接受健康志愿者

入选标准

  • Healthy young males (18-26 years) bearing no acute or chronic illness for the last 3 months previously to the experiment

排除标准

  • Use of any drugs, tobacco, alcohol 2 months prior to the experiment. The investigators also planned to exclude those who for any reason do not comply with the protocols

研究组 & 干预措施

Oral Saline

Experimental

Ingestion of 0.9% saline solution

干预措施: Oral saline (Other)

Intravenous Saline

Active Comparator

Intravenous infusion of 0.9% saline solution

干预措施: Intravenous saline (Other)

结局指标

主要结局

Body Composition

时间窗: 2 hours

. After having voided the bladder they were weighted to the nearest 0.1 kg and their heights were measured to the nearest 0.01 m with a estadiometer. Body mass was then calculated. Bioelectrical impedance analysis was performed with single-frequency (50 kHz) device (Bodystat 1500; Bodystat Ltd., Isle of Man, U.K.) using tetrapolar distal limb electrodes. TBW, fatty mass and lean body mass were calculated using regression equations programmed into the devices

次要结局

  • Serum electrolytes(2 hours)

研究者

发起方
Federal University of Mato Grosso
申办方类型
Other
责任方
Principal Investigator
主要研究者

Jose Eduardo de Aguilar-Nascimento

Full Professor

Federal University of Mato Grosso

研究点 (2)

Loading locations...