跳至主要内容
临床试验/NCT04790656
NCT04790656已完成不适用

Effects of Continuous Positive Airway Pressure (CPAP)and Physical Exercise on Cycle Ergometer in Myocardial Revascularization Post-surgical Patients

Riphah International University2 个研究点 分布在 1 个国家目标入组 102 人开始时间: 2020年10月14日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
102
试验地点
2
主要终点
6 min walk distance

研究概览

简要总结

The aim is to evaluate the effectiveness of physical exercise on a cycle ergometer combine with CPAP in the postoperative period after myocardial revascularization

详细描述

Physical exercise on a cycle ergometer combine with CPAP as an adjunct to the rehabilitation of hospitalized subjects who will undergo myocardial revascularization will be safe, decrease the length of stay in the ICU, and help maintain functional capacity

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Treatment
盲法
Double (Participant, Investigator)

入排标准

年龄范围
40 Years 至 75 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Subjects who have undergone myocardial revascularization surgery
  • An ejection fraction of greater than40%
  • Post operative mechanical ventilation for <12hours
  • No definite diagnosis of chronic obstructive pulmonary disease and asthma

排除标准

  • With complications in post operative period (e.g., Artial fibrillation, prolonged mechanical ventilation)
  • Hemodynamically unstable patients
  • Intolerance to CPAP(continuous positive airway)mask

结局指标

主要结局

6 min walk distance

时间窗: 4th day

The six minute walking test (6MWT) was developed by the American Thoracic Society and it was officially introduced in 2002, coming along with a comprehensive guideline. The 6 Minute Walk Test is a sub-maximal exercise test used to assess aerobic capacity and endurance. The distance covered over a time of 6 minutes is used as the outcome by which to compare changes in performance capacity

Modified Borg scale

时间窗: 4th day

The Modified Borg Dyspnoea Scale is most commonly used to assess symptoms of breathlessness. Despite being a subjective measure of exercise intensity, RPE scales provide valuable information when used correctly.

1 min sit to stand test

时间窗: 4th day

Vaidya et al reported that 1-minute STS test is a simple and sensitive test and appears to be a practical, reliable, valid, and responsive alternative for measuring exercise capacity, particularly where space and time are limited

Digital Monovacumeter

时间窗: 4th day

The manovacuometer is a simple, quick and non-invasive test which measures the maximal respiratory pressures (MRS).Digital manovacuometer is a reliable and valid instrument for assessing maximum inspiratory pressure and maximum expiratory pressure in healthy subjects

次要结局

未报告次要终点

研究者

申办方类型
Other
责任方
Sponsor

研究点 (2)

Loading locations...

相似试验

Interventional Effects on Myocardial... | 临床试验