临床试验/NCT03456427
NCT03456427已完成不适用

Patient-Assisted Compression in 3D - Impact on Image Quality and Workflow

GE Healthcare2 个研究点 分布在 1 个国家目标入组 36 人开始时间: 2018年1月4日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
GE Healthcare
入组人数
36
试验地点
2
主要终点
Percentage of Acceptable Overall Image Quality

研究概览

简要总结

Patient-assisted compression (PAC) allows the patient to participate in controlling the amount of compression force during mammography and is a personalized approach that has demonstrated successful reduction in discomfort experienced during mammography. General Electric Healthcare's Senographe Pristina, an innovative mammography platform that provides both two-dimensional (2D) and three-dimensional (3D) imaging capabilities, offers both standard and patient-assisted compression modes. This study will evaluate image quality and clinical workflow as it relates to use of PAC with the Senographe Pristina 3D.

详细描述

The study population will consist of adult asymptomatic women presenting for screening 2D mammography. One breast of each subject will be identified as the "breast of interest," which will undergo study-specific 3D imaging consisting of two-view (craniocaudal and mediolateral oblique) PA compression and image acquisition, followed by two-view technologist-controlled (TC) compression and image acquisition. The breast of interest will be randomly assigned to either the first breast imaged during the exam or the second breast imaged. TC compression and imaging, and procedures performed on the subject's other breast will be conducted per standard of care.

Following image acquisition, 3D image quality evaluation will be conducted by Mammography Quality Standards Act-qualified readers. Prior to the reading session, images will be de-identified and the following information will be removed from the DICOM header to blind readers to the compression mode used during acquisition: time stamp, compression force, and breast thickness. The image sets will also be randomized for presentation during the image attribute reviews. Two (2) readers will evaluate each PAC and TC compression image set collected from each subject's breast of interest and assess the acceptability of image attributes, as defined in the Guidance for Industry and FDA Staff - Class II Special Controls Guidance Document: Full-Field Digital Mammography System (2012). A third reader will provide adjudication, if there is disagreement for a given image set's overall clinical image quality.

Workflow data, including the incidence of technologist intervention during acquisition and need for repeat image acquisition, will also be collected.

The proportion of PAC image sets that are of equal or higher acceptability than TC image sets will be calculated. A 95% confidence interval will be calculated using asymptotic method with continuity correction. The proportion of image sets indicated for repeated image acquisition when using PA mode or TC mode will be summarized. Other endpoint data will be summarized using descriptive statistics. No statistical hypothesis is being tested in this study.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Device Feasibility
盲法
None

入排标准

年龄范围
40 Years 至 —(Adult, Older Adult)
性别
Female
接受健康志愿者

入选标准

  • Are women aged 40 years or older;
  • Are asymptomatic and scheduled for screening mammography;
  • Have left and right breasts;
  • Have breast sizes compatible with the dimensions of a 24 x 31 cm image detector, without anatomical cut-off;
  • Are documented as non-pregnant based on the investigator's medical judgment and in consideration of local clinical practice standards for evidence of non-pregnancy;
  • Are able and willing to comply with study procedures; and
  • Are able and willing to provide written informed consent to participate.

排除标准

  • Are women aged 40 years or older;
  • Are asymptomatic and scheduled for screening mammography;
  • Have left and right breasts;
  • Have breast sizes compatible with the dimensions of a 24 x 31 cm image detector, without anatomical cut-off;
  • Are documented as non-pregnant based on the investigator's medical judgment and in consideration of local clinical practice standards for evidence of non-pregnancy;
  • Are able and willing to comply with study procedures; and
  • Are able and willing to provide written informed consent to participate.

结局指标

主要结局

Percentage of Acceptable Overall Image Quality

时间窗: 1 Day

The primary objective is to compare the percentage of acceptable overall image quality in unilateral two-view (CC and MLO) breast images acquired using Patient-Assisted Compression and Technologist Compression modes.

次要结局

  • Percentage of Acceptable Mammographic Attributes(1 Day)
  • Number of Repeat Image Acquisitions(1 Day)

研究者

发起方
GE Healthcare
申办方类型
Industry
责任方
Sponsor