跳至主要内容
临床试验/NCT06469034
NCT06469034已完成不适用

Use of Head-mounted Display for Ultrasound-guided Central Venous Catheterization in Adults: a Randomized Controlled Study

The Second Hospital of Anhui Medical University1 个研究点 分布在 1 个国家目标入组 124 人开始时间: 2024年7月1日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
124
试验地点
1
主要终点
Total catheterization time

研究概览

简要总结

Head-mounted displays (HMD) in medical practice are current research topics. The goal of this clinical trial is to learn if HMD would improve the safety and efficacy in ultrasound-guided central venous catheterization. The main questions it aims to answer are: Does HMD reduce the procedure time and increase the catheterization success rate in ultrasound-guided central venous catheterization. Does HMD increase the satisfaction score of operators and patients. Researchers will compare HMD with the conventional ultrasound in central venous catheterization. Operators will receive either HMD or conventional ultrasound machine to guide internal jugular vein catheterization. The procedure time, puncture success rate, complication and satisfactory score will be recorded.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Treatment
盲法
Triple (Participant, Investigator, Outcomes Assessor)

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Patients scheduled for elective surgery under general anesthesia
  • Patients indicative of internal jugular vein catheterization.

排除标准

  • 1. A recent history of internal jugular vein puncture, wound, infection, hematomas, nerve injury at the venous cannulation site;
  • Combined with peripheral vascular disease, coagulopathy;
  • History of opiate abuse;
  • Pre-existing chronic pain, mental or neurological disorders;
  • Allergy to local anesthetics or gel;
  • Unstable vital signs, including hypertension, hypotension or arrhythmia

结局指标

主要结局

Total catheterization time

时间窗: From application of the ultrasound probe to skin to the end of catheterization

The total catheterization time is defined as the period between the probe positioning on the patient's skin and insertion of the catheter, irrespective of the attempt number of the venous catheterization.

次要结局

  • Ultrasound scan time(From application of the ultrasound probe to skin to the end of catheterization)
  • Venous access time(From application of the ultrasound probe to skin to the end of catheterization)
  • Number of needle redirections(From application of the ultrasound probe to skin to the end of catheterization)
  • Number of looks at the monitor(From application of the ultrasound probe to skin to the end of catheterization)
  • Time spent looking at the patient(From application of the ultrasound probe to skin to the end of catheterization)
  • Time spent looking at the monitor(From application of the ultrasound probe to skin to the end of catheterization)
  • First-attempt success rate of internal jugular vein cannulation(From application of the ultrasound probe to skin to the end of catheterization)
  • The second attempt success rate(From application of the ultrasound probe to skin to the end of catheterization)
  • Number of attempts of needle puncture(From application of the ultrasound probe to skin to the end of catheterization)
  • The incidence and severity of complications(From application of the ultrasound probe to skin to the catheter removal)
  • pain score of procedure(From application of the ultrasound probe to skin to the end of catheterization)
  • Failure rate of catheterization.(From application of the ultrasound probe to skin to the end of catheterization)
  • Satisfaction score of patients(From application of the ultrasound probe to skin to the end of catheterization)
  • Satisfaction score of operators(From application of the ultrasound probe to skin to the end of catheterization)
  • The diameter and depth of the internal jugular vein(From application of the ultrasound probe to skin to the beginning of puncture)
  • Number of attempts of guidewire insertion(From application of the ultrasound probe to skin to the end of catheterization)
  • Number of probe repositioning(From application of the ultrasound probe to skin to the end of catheterization)
  • The distance of tip of the needle from central line of vessel(From application of the ultrasound probe to skin to the end of catheterization)

研究者

发起方
The Second Hospital of Anhui Medical University
申办方类型
Other
责任方
Principal Investigator
主要研究者

Yun Wu

Doctor, Anesthesiology, Principal Investigator

The Second Hospital of Anhui Medical University

研究点 (1)

Loading locations...

相似试验