Insertion Angle and Needle Visualization During Ultrasound Guided Internal Jugular Vein Cannulation
试验速览
- 阶段
- 不适用
- 入组人数
- 150
- 试验地点
- 1
- 主要终点
- success rate
研究概览
简要总结
Ultrasound guidance has been established as an effective and safe method during insertion of internal jugular vein catheter.. Needle visualization during advancement toward the vein has a great impact on both safety and success of the procedure. Clinicians have adopted variable techniques to increase needle visualization including changing needle- probe relation (in-plane vs. out-of-plane), or using specific ultrasound needles The angle between the inserting needle and the probe lying on patient skin affects both the distance to the vein and the length of the needle part travelling through the us beam
研究设计
- 研究类型
- Interventional
- 分配方式
- Randomized
- 干预模型
- Parallel
- 主要目的
- Prevention
- 盲法
- Single (Participant)
入排标准
- 年龄范围
- 18 Years 至 65 Years(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •all patients requiring central line insertion
排除标准
- •coagulopathy
- •neck surgeries
研究组 & 干预措施
angle 30 group
During central line insertion, After choosing the proper position, the skin was infiltrated with %1 lidocaine. The vein will be localized using linear ultrasound probe (PLT-805AT, 8 MHz, Toshiba Tokyo, Japan) attached to ultrasound machine (Xario, Toshiba Tokyo Japan). The needle will be advanced guided by the ultrasound probe with needle skin angle 30-40 degree.
干预措施: needle PLT-805AT (Device)
angle 30 group
During central line insertion, After choosing the proper position, the skin was infiltrated with %1 lidocaine. The vein will be localized using linear ultrasound probe (PLT-805AT, 8 MHz, Toshiba Tokyo, Japan) attached to ultrasound machine (Xario, Toshiba Tokyo Japan). The needle will be advanced guided by the ultrasound probe with needle skin angle 30-40 degree.
干预措施: Ultrasound (Device)
angle 50 group
During central line insertion,After choosing the proper position, the skin was infiltrated with %1 lidocaine. The vein will be localized using linear ultrasound probe (PLT-805AT, 8 MHz, Toshiba Tokyo, Japan) attached to ultrasound machine (Xario, Toshiba Tokyo Japan). The needle will be advanced guided by the ultrasound probe with needle skin angle 50-60 degree
干预措施: needle PLT-805AT (Device)
angle 50 group
During central line insertion,After choosing the proper position, the skin was infiltrated with %1 lidocaine. The vein will be localized using linear ultrasound probe (PLT-805AT, 8 MHz, Toshiba Tokyo, Japan) attached to ultrasound machine (Xario, Toshiba Tokyo Japan). The needle will be advanced guided by the ultrasound probe with needle skin angle 50-60 degree
干预措施: Ultrasound (Device)
angle 70 group
During central line insertion,After choosing the proper position, the skin was infiltrated with %1 lidocaine. The vein will be localized using linear ultrasound probe (PLT-805AT, 8 MHz, Toshiba Tokyo, Japan) attached to ultrasound machine (Xario, Toshiba Tokyo Japan). The needle will be advanced guided by the ultrasound probe with needle skin angle 60-80 degree
干预措施: needle PLT-805AT (Device)
angle 70 group
During central line insertion,After choosing the proper position, the skin was infiltrated with %1 lidocaine. The vein will be localized using linear ultrasound probe (PLT-805AT, 8 MHz, Toshiba Tokyo, Japan) attached to ultrasound machine (Xario, Toshiba Tokyo Japan). The needle will be advanced guided by the ultrasound probe with needle skin angle 60-80 degree
干预措施: Ultrasound (Device)
结局指标
主要结局
success rate
时间窗: 24 hours starting from central line insertion
次要结局
未报告次要终点