Comparison of Two Round Face Masks During Neonatal Resuscitation

University of Alberta2 个研究点 分布在 1 个国家目标入组 56 人开始时间: 2013年3月最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
56
试验地点
2
主要终点
Difference in Percentage of Leak

研究概览

简要总结

Most premature babies have difficulty breathing at birth and need help (what we call resuscitation). The treatment for this is to gently inflate their lungs with a resuscitation device and a facemask. The device commonly used is a T-Piece infant resuscitator (which we call the T-Piece) and is used at The Royal Alexandra Hospital and all round the world.

To gentle inflate an infants lung the clinical team put a face mask around your baby's mouth and nose. The clinical team tries to achieve a good seal between the face and the mask. A problem of mask ventilation is that air can escape between the mask and the face (what we call mask leak). Currently, two different types of facemasks ("Laerdal mask" or "Fisher & Paykel mask") are routinely used in the delivery room at The Royal Alexandra Hospital.

The purpose of this study is to find out if one facemask is leaking less between the face and the mask.

详细描述

We will use a Laerdal round mask (Laerdal, Stavanger, Norway) compared to a Fisher & Paykel (FP) (Fisher & Paykel Healthcare, Auckland, New Zealand) 'round' neonatal resuscitation mask. The two point top hold for Laerdal 'round' mask and the rim hold for the Fisher & Paykel mask.

A Respiratory Function Monitor will be placed between the face mask and the ventilation device. It uses a small (dead space 1 mL) flow sensor to measure gas flow in and out of a face mask. This signal is automatically integrated to provide inspired and expired tidal volume. The difference equals the leak from the face mask. It also calculates respiratory rate and minute ventilation, measures spontaneous inspirations and ventilation pressures. The signals of airway flow, tidal volumes, airway pressure, inspired oxygen concentration, temperature, blood pressure, oxygen saturation, heart rate will be digitised and recorded at 200Hz using the Spectra physiological recording program (a customised neonatal respiratory physiology program).

We will compare the % of mask leak within the two face masks.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Treatment
盲法
Single (Outcomes Assessor)

入排标准

年龄范围
— 至 30 Minutes(Child)
性别
All
接受健康志愿者

入选标准

  • Preterm infants <32 weeks gestation born at The Royal Alexandra Hospital who require resuscitation in the delivery room will be recorded.

排除标准

  • Infants will be excluded from final analysis if they have a congenital abnormality or condition that might have an adverse effect on breathing or ventilation, including: Congenital Diaphragmatic Hernia. Infants will also be excluded if their parents refuse to give consent to this study.
  • Participants will be included in the first minutes after birth if they require mask ventilation for poor respiratory effort. Data will be collected from the Hospital chart until discharge at around 40 weeks gestation.

结局指标

主要结局

Difference in Percentage of Leak

时间窗: during mask ventilation in the first 5 minutes after birth

Primary outcome: Difference in percentage of Leak

次要结局

未报告次要终点