NCT06789627已完成不适用
Indirect CAD/CAM Removable Partial Denture Frameworks: a Comparative Study
适应症
干预措施
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 入组人数
- 30
- 试验地点
- 1
- 主要终点
- Oral Health Related Quality of Life (OHRQoL)
研究概览
简要总结
The aim of this study was to compare CAD Poly ether ether ketone (PEEK) RPD to CAD metallic RPD in treating partial edentulism in terms of Oral health related quality of life
研究设计
- 研究类型
- Interventional
- 分配方式
- Randomized
- 干预模型
- Parallel
- 主要目的
- Treatment
- 盲法
- Single (Outcomes Assessor)
入排标准
- 年龄范围
- 20 Years 至 50 Years(Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Patients with bilateral free end saddles in the mandible (Kennedy class I) with the last standing abutment second premolar
- •Opposing dentition is fully intact or restored to be intact
- •Adequate inter-arch space of at least 7mm
- •Angle's class I maxilla-mandibular relationship
- •Patients with no periodontal disease and good oral hygiene
- •Cooperative patients showing motivation to follow-up
排除标准
- •Periodontal affection of the abutment teeth
- •Skeletal mal-relationship
- •Unmotivated patients to maintain adequate oral hygiene and to follow up---- ---- Patients with neuro-mascular disorders
- •Systemic disease affecting periodontal health like uncontrolled diabetes
研究组 & 干预措施
RPD with metallic framework
Active Comparator
Indirectly CAD/CAM produced Metallic framework
干预措施: RPD with metallic framework (Other)
RPD with PEEK framework
Experimental
Indirectly CAD/CAM produced PEEK framework
干预措施: RPD with PEEK framework (Other)
结局指标
主要结局
Oral Health Related Quality of Life (OHRQoL)
时间窗: 2 years
measured by Oral Health Impact Profile- 14 Minimum score 0 , Maximum score 56 higher scores indicate worse OHRQoL
次要结局
- Cost effectiveness(1 year)
研究者
Hend Mahmoud Mohamed Hegazi
Prinicipal investigator
Cairo University
研究点 (1)
Loading locations...
相似试验
尚未招募
不适用
Retention of CAD Metallic and Poly Ether Ether Ketone (PEEK) FrameworksRetentionNCT05670899Cairo University20
Unknown
不适用
Comparison Between Injection Molded PEEK Framework and Cobalt Chromium Framework in Removable Partial Denture Regarding RetentionMandibular Prosthesis UserNCT03777280Cairo University30
已完成
不适用
Patient Centered Outcomes and Marginal Bone Changes in CAD/CAM Metallic and (PEEK) Partial Denture FrameworksPatient SatisfactionNCT05622448Cairo University30
Unknown
不适用
Comparison Between Injection Molded PEEK Framework and Cobalt Chromium Framework Removable Partial Dentures Regarding Biting ForceMandibular Prosthesis UserNCT03777423Cairo University30
进行中(未招募)
Unknown
Clinical study of Removable Partial Dentures constructed with different structural materialsJaw, EdentulousC07.465.550RBR-4ccdqh6Faculdade de Odontologia de Piracicaba - FOP/UNICAMP