Position Differences and Physical Performance Among Female Team Handball Players
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 发起方
- 入组人数
- 40
- 试验地点
- 1
- 主要终点
- Lower Extremity Vertical Power
研究概览
简要总结
Our study was conducted to compare the physical performances of the upper extremity and lower extremity of handball players according to the positions they played.
In this cross-sectional study, a total of 39 elite female handball players with at least of 5 years playing experience were tested.Maximal voluntary isometric (MVIC) knee flexion and extension strength were measured using a handheld dynamometer (HDD) (Lafayette Instrument Company, Lafayette, IN). Lower extremity vertical power was identified through the use of the VertiMetric (Lafayette Instrument Company, Lafayette, IN) according to protocols suggested by Ambegaonkar et al. Trunk extension endurance was measured using the Biering-Sorensen test as previously described.The Davies test (DT) was used to assess upper body agility and stabilization.The Closed Kinetic Chain Upper Extremity Stability Test (CKCUEST) was utilized to assess shoulder performance function and stability according to protocol suggested by Goldbeck and Davies.The Shark Skill Test (SST) was developed in order to assess lower extremity agility and neuromuscular control.
研究设计
- 研究类型
- Observational
- 观察模型
- Other
- 时间视角
- Cross Sectional
入排标准
- 年龄范围
- 18 Years 至 40 Years(Adult)
- 性别
- Female
- 接受健康志愿者
- 是
入选标准
- 未提供
排除标准
- 未提供
结局指标
主要结局
Lower Extremity Vertical Power
时间窗: 2 weeks
Lower extremity vertical power was identified through the use of the VertiMetric (Lafayette Instrument Company, Lafayette, IN) according to protocols suggested by Ambegaonkar et al.
Trunk Extension Endurance
时间窗: 2 weeks
Trunk extension endurance was measured using the Biering-Sorensen test as previously described.
Lower Limb Performance
时间窗: 2 weeks
The Shark Skill Test (SST) was developed in order to assess lower extremity agility and neuromuscular control.
Muscle Strength
时间窗: 2 weeks
Maximal voluntary isometric (MVIC) knee flexion and extension strength were measured using a handheld dynamometer (HDD) (Lafayette Instrument Company, Lafayette, IN).
Upper Limb Performance
时间窗: 2 weeks
The Davies test (DT) was used to assess upper body agility and stabilization.The Closed Kinetic Chain Upper Extremity Stability Test (CKCUEST) was utilized to assess shoulder performance function and stability according to protocol suggested by Goldbeck and Davies.
次要结局
未报告次要终点
研究者
caglar soylu
Çağlar Soylu
Ankara Yildirim Beyazıt University
