Digital Twin and Ml-basEd MOdel of TEVAR Interventions
试验速览
- 阶段
- 不适用
- 状态
- 招募中
- 入组人数
- 5,000
- 试验地点
- 1
研究概览
简要总结
The study aims to collect clinical data and pseudonymized CT images of patients undergoing TEVAR in order to create an anatomical digital twin capable of simulating procedural outcomes and training machine learning (ML) algorithms. This approach will support predictive models that may assist physicians in selecting the optimal medical device, improving pre-TEVAR planning, and predicting post-TEVAR complications.
详细描述
In recent years, Thoracic Endovascular Aortic Repair (TEVAR) has become increasingly utilized for the treatment of thoracic aortic pathologies. Over the past two decades, the adoption of TEVAR has grown significantly, progressively replacing open surgery as the preferred treatment approach in many cases. Initially designed for interventions involving the descending thoracic aorta, TEVAR is now being extended to more complex anatomies, including the aortic arch and even regions closer to the aortic root.
Successful TEVAR procedures rely on accurate preoperative planning and detailed clinical assessment to optimize patient outcomes. Although TEVAR offers several advantages over open surgery, including reduced procedural risk, shorter recovery time, and lower morbidity, it is not without limitations. Major complications include endoleaks, stent-induced new entry tears, vessel obstruction, and stent migration, all of which may significantly affect patient prognosis. Despite existing manufacturer guidelines and deployment strategies, these complications remain difficult to predict.
Previous studies have reported endoleak rates ranging from 4% to 15%, stent migration rates between 1.0% and 2.8%, and device-related complications occurring in up to 38% of cases. Recent advances in computational modeling have demonstrated considerable potential for improving TEVAR planning and risk prediction. Finite element analysis (FEA) and fluid-structure interaction (FSI) simulations have proven valuable for assessing stent behavior within patient-specific anatomies. Through in silico simulations, different stent types and diameter configurations can be virtually tested, providing surgeons with critical insights for clinical decision-making.
However, despite their high accuracy, these techniques are computationally intensive and require large datasets as well as specialized expertise, limiting their accessibility for routine clinical practice. To address these challenges, numerical models (e.g., finite element simulations) and machine learning (ML) approaches represent promising alternatives for real-time, data-driven perioperative decision support. By integrating finite element simulations with clinical imaging data, ML algorithms can be trained to predict procedural outcomes, optimize prosthesis selection, and estimate post-interventional risks. This approach not only enhances pre-procedural planning but also facilitates postoperative risk assessment, ultimately contributing to improved patient management.
A critical challenge in developing robust ML models for TEVAR planning is the limited accessibility of high-quality annotated datasets and their integration into clinical workflows. To overcome this limitation, the study proposes a comprehensive methodology aimed at:
研究设计
- 研究类型
- Observational
- 观察模型
- Cohort
- 时间视角
- Retrospective
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •≥18 Years and older (Adult, Older Adult)
- •Female and male
- •Received TEVAR for: Chronic or acute dissection, Aneurysm, Penetrating aortic ulcer, aortic thrombus, intramural hematoma or traumatic injury
排除标准
- •Younger than 18 years old
- •Received TEVAR in surgical graft that replaced native aorta
- •Poor CT image quality that leads to failure in generating a high-fidelity 3D FE model of patient anatomy (no preoperative multidetector contrast-enhanced CT-scan available, preoperative CTscan slice thickness greater than 1mm, preoperative CT-scan with artifacts, motion artifacts due to the presence of other implanted devices affecting the region of interest)
