Patient Ventilator Asynchrony as a Predictor of Weaning Failure in Mechanically Ventilated COPD Patients

Reham Mohammed Elmorshedy1 个研究点 分布在 1 个国家目标入组 100 人开始时间: 2018年2月15日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
100
试验地点
1
主要终点
To study effect of different types of ventilator asynchrony on weaning in mechanically ventilated COPD patients

研究概览

简要总结

Patient ventilator asynchrony is a common problem in mechanically ventilated patients .It is associated with adverse effects including increased work of breathing, patient discomfort, increased need for sedation, prolonged mechanical ventilation , weaning difficulties and weaning failure. 100 mechanically ventilated COPD patients were enrolled in this prospective study .Detection of patient ventilator asynchrony was done on 30-minute sessions at 12, 24, 36, and 48 hours following intubation by visual assessment of pressure, flow and volume graphs on ventilator .

详细描述

Patient-ventilator asynchrony is defined as a lack of organization between the patient and ventilator timing of both inspiration and expiration . It is a commonly reported problem during mechanical ventilation. Thille et al. found that 24% of patients developed asynchrony in at least ten percent of their breaths, moreover they stated that the most frequent asynchronies was each of ineffective triggering and double triggering . Eighty percent of chronic obstructive pulmonary disease (COPD) patients experienced ineffective triggering, where it is considered the most frequent asynchrony in this group of patients. Asynchrony between Patient and ventilator also leads to prolonged duration of invasive ventilation, and increase possibility of weaning failure.

Both spread and intensity of asynchrony during the early phase of weaning in COPD patients has never satisfactorily described. The aim of the current study was to describe the patient-ventilator asynchrony and its impact on weaning outcome in mechanically ventilated COPD patients.

研究设计

研究类型
Observational
观察模型
Cohort
时间视角
Prospective

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • All COPD patients who were diagnosed after history ,physical examination radiology and pulmonary function tests and required mechanical ventilation.

排除标准

  • Age < 18 years
  • Tracheostomy
  • Failure to trigger breaths even in cases of receiving neuromuscular blocking agents.
  • Encephalopathy which is not caused by hypercapnia or hypoxemia either post arrest or due to cerebrovascular stroke
  • Patients with unplanned weaning
  • COPD patients where intubation not related to exacerbation e.g. acute pulmonary edema.

结局指标

主要结局

To study effect of different types of ventilator asynchrony on weaning in mechanically ventilated COPD patients

时间窗: One year

Detection of patient ventilator asynchrony was done on 30-minute sessions following intubation by visual assessment of pressure, flow and volume graphs on ventilator .Repeated measures are done from the begining of mechanical ventilation and type of asynchronies including ineffective trigger double trigger, auto trigger , delayed cycle, early cycle and flow asynchrony. were recorded.