跳至主要内容
临床试验/NCT05433961
NCT05433961终止1 期

Functional and Structural Assessment of Endobronchial Valve Recipients Using Dynamic Hyperpolarized Xenon-129 MRI

Xemed LLC1 个研究点 分布在 1 个国家目标入组 27 人开始时间: 2023年10月20日最近更新:
适应症
干预措施
相关药物

试验速览

阶段
1 期
状态
终止
发起方
Xemed LLC
入组人数
27
试验地点
1
主要终点
Lung function changes from baseline (pre) to follow-up (post) EBV procedure as measured with hyperpolarized xenon MRI.

研究概览

简要总结

This study proposes to use hyperpolarized xenon-129 Magnetic Resonance Imaging (MRI) to study lung function of COPD patients who will receive endobronchial valve (EBV) therapy as part of their clinical standard-of-care. Once inhaled, HP xenon can provide information to imagers regarding functionality across specific regions of the lungs through the assessment of the replacement of air during the normal breathing cycle, how much oxygen is in the airspaces, and if the normal spongy tissue structure has been compromised by lung disease. Pre- (baseline) and post-EBV (follow-up) lung function imaging with HPXe will potentially lead to be better understand disease progression and treatment mechanism.

详细描述

This study will be assessing the pulmonary function of COPD patients receiving endobronchial valve (EBV) therapy as part of their clinical care by using HP 129Xe MRI in an effort to evaluate the imaging technique's performance in identifying abnormal lung function and micromorphology in patients receiving this therapy. HP Xe MRI study visits will last 1-2 hours for each subject, with the possibility of multiple follow-ups in longitudinal studies. The investigators plan to recruit volunteer patients who are scheduled to receive EBV therapy for the treatment of COPD as part of their clinical standard-of-care. Patients will be imaged at at least two time point, pre-EBV (baseline), and ~45 days post-EBV (follow-up).

Subjects will provide a brief medical history and perform pulmonary function testing (PFT) prior to inhalation of HP xenon-129. If a subject has performed a PFT at the Hospital of the University of Pennsylvania or Temple University Hospital within one month of the study visit and the results are accessible by the research team, subjects will not be required to repeat PFTs for the purpose of imaging.

During a typical HXe MRI session, subjects will first be imaged using standard 1H MRI to generate an anatomical reference image. This will be followed by the inhalation of a small amount (~200 ml) of HP 129Xe from a Tedlar™ bag to perform a frequency calibration, as well as determine the effective flip-angle to be used for the subject. Finally, the subject will sequentially inhale up to 50 breaths of hyperpolarized 129Xe from a gas mixing apparatus designed to oxygenate and dilute the gas, maintaining near normoxic conditions and approximately 10% xenon concentration. During this period, the lungs will be continuously imaged using a 3D sequence and a very low flip-angle (~3 degrees) pulse. The subject will be coached to maintain a reasonably steady breathing cadence of 10-15 breaths per minute, depending on their size and natural breathing rate, but will be otherwise unconstrained with respect to breath timing and volume.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Diagnostic
盲法
None

入排标准

年龄范围
18 Years 至 85 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • COPD patients scheduled to receive endobronchial valve therapy
  • Patient is conscious, cooperative and agrees to return for scheduled visits and tests

排除标准

  • Patients less than 18 years old
  • Patients known to be pregnant - a positive pregnancy test will be used to respectively exclude pregnant patients
  • Any known contraindication to MRI examination
  • Anyone with an implanted metal device
  • Inability to provide informed consent
  • A language, communication, cognitive or behavioral impairment that might interfere with fully informed participation in the study.
  • History of uncompensated organ failure (i.e. organ failure that is not stabilized through medical intervention), which will be assessed by the PI.
  • Homelessness or other unstable living situation
  • Active drug or alcohol dependence
  • Claustrophobia
  • Subjects weighting more than 300 pounds.
  • Subjects with chest size larger than the bore of MRI machine from the study.

研究组 & 干预措施

Hyperpolarized Xenon MRI assessment of lung function in endobronchial valve treated COPD patients

Experimental

Volunteer patients scheduled for receiving endobronchial valve treatment as part of clinical care will be imaged with hyperpolarized xenon prior and post EBV for assessing lung function and improvement.

干预措施: MagniXene Hyperpolarized Xenon MRI (Drug)

结局指标

主要结局

Lung function changes from baseline (pre) to follow-up (post) EBV procedure as measured with hyperpolarized xenon MRI.

时间窗: 90 days

Endobronchial valve receiving patients will have HPXe MRI sessions for assessing lung function parameters as measured from inhaled hyperpolarized xenon distribution inside the lungs. Fractional ventilation will be obtained based on the signal build up for dynamic breathing of HP 129Xe and room air. TV and FRC will be determined based on the signal build up at inhalation and the gas remaining in the lung at exhalation. τ will be determined by the signal intensity reaching other parts of the lung relative to the signal intensity in the trachea. ADC will be determined using diffusion sensitizing gradients according to standard imaging protocols. Additionally, dissolved phase MR imaging of HP 129Xe will be assessed in order to obtain information regarding microstructural abnormalities that affect gas uptake into the blood. All these parameters are mapped as 3D lung images, and they will be compared between baseline and follow-up session.

次要结局

未报告次要终点

研究者

发起方
Xemed LLC
申办方类型
Industry
责任方
Sponsor

研究点 (1)

Loading locations...

相似试验